Secutech Radio modules ST002012 データシート

製品コード
ST002012
ページ / 32
Page 20
 
Security & Electronic Technologies GmbH
 
 
 
Putting into service a SECU-DATA 142xx 
1.  Connect  the  probes  and  the  evaluation  equipment  to  the  SECU-
DATA 142xx units 
 
2.  Turn on the DC power supply 
in the range of +11 V … +40 V 
 
3.  Match one pair of instruments together: 
Set the same channel block number on both instruments 
– factory 
default is block #6 
– details se chapter Settings-Selection of the 
RF-channel block 
Match the instruments together 
– detail see chapter Settings-
Matching two SECU-DATA xxxx 
 
4.  Both  SECU-DATA  142xx  modules  will  establish  an  RF-inter-
connection immediately, the green RF-indicators are blinking. After 
some seconds they are continuously on 
– the connection is active. 
 
5.  The  current  on  the  input  of  the  SECU-DATA  142xM  is  reproduced 
precisely  on  the  output  of  the  SECU-DATA  142xC  for  evaluation 
with the controller equipment. 
 
6.  Check  the  current  values  on  the  evaluation  instrument  for  
plausibility.  
 
The commissioning is completed now successfully. 
 
Dismantling 
Important:  
If you detect any damage of the housing, controls, connection wires or other 
connected devices, immediately disconnect the unit from the power supply.  
If  you  cannot  ensure  the  safe  operation  of  the  device,  immediately  shut 
down  the  unit  and  the  respective  accessories,  secure  them  against  inad-
vertent  switching  on
,  mark  them  clearly  as  “defective,  out  of  order”  and 
send them in to an authorized service facility.