Secutech Radio modules ST002005 データシート

製品コード
ST002005
ページ / 40
Page 24
 
Security & Electronic Technologies GmbH
 
 
 
Putting into service a SECU-DATA 42xx 
1.  Connect  the  probes  and  the  evaluation  equipment  to  the  SECU-
DATA 42xx units 
 
2.  Turn on the DC power supply 
in the range of +11 V … +40 V 
 
3.  Match 
one 
pair 
of 
instruments 
together: 
Set the same channel block number on both instruments 
– factory 
default  is  block  #6 
– details se chapter  Settings-Selection  of  the 
RF-channel 
block 
 
Match  the  instruments  together 
–  detail  see  chapter  Settings-
Matching two SECU-DATA xxxx 
 
4.  Both  SECU-DATA  42xx  modules  will  establish  an  RF-inter-
connection immediately, the green RF-indicators are blinking. After 
some seconds they are continuously on 
– the connection is active. 
 
5.  The  current  on  the  input  of  the  SECU-DATA  42xM  is  reproduced 
precisely on the output of the SECU-DATA 42xC / 142xC for evalu-
ation with the controller equipment. 
 
6.  Check  the  current  values  on  the  evaluation  instrument  for  
plausibility.  
 
 
The commissioning is completed now successfully.