Secutech Radio modules ST002005 データシート

製品コード
ST002005
ページ / 40
Security & Electronic Technologies GmbH
 
Page 35 
 
 
SECU-DATA 500C  
Relay outputs (pins 3-4, 5-6, ignition protection: 
“ib”): 
U
= 30 V, I
= 500 mA, C
I  
~ 0, L
= ~ 0 
For the transmission of the status of the two relay contacts no further speci-
fication is required. Rated switching capacity: 30 V / 500 mA. 
 
Technical specification of SECU-DATA 600M - NAMUR 
ATEX parameters: 
 
NAMUR-probe (pins 3-4, ignition protection: 
“ia”): 
U
= 10 V, I
= 14 mA, C
= 1 µF, L
= 2 mH 
Switching thresholds depending on the current flow through the  
NAMUR probe:
 
Probe current 
Re1 
Re2 
Meaning 
0 … 0.4 mA 
OFF 
ON 
Probe fault, “interruption”
 
1 … 2 mA 
ON 
OFF  Filling is in progress 
2 … 6 mA 
OFF 
OFF  Tank full 
> 6 mA 
OFF 
ON 
Probe fault, 
“short”
 
Technical specification of SECU-DATA 710M - TRbF 
ATEX parameters : 
Connector for SECU-DATA 710B (pins 3-4, ignition protection: 
“ia”): 
U
= 23.1 V, I
= 145.8 mA, C
~ 0, L
~ 0 
TRbF-probe connector (pins 5-6, ignition protection: 
“ia”): 
U
= 23.1 V, I
= 145.8 mA, C
= 60 nF, L
O
 = 2 mH 
 
Thresholds for the current flow through the TRbF probe: 
Probe current 
Re1 
Re2 
Meaning 
0 … 6 mA 
OFF 
ON 
Probe fault, 
“interruption” 
6 … 40 mA 
ON 
OFF  Filling is permissible 
>42 mA 
OFF 
OFF  Filling not permissible 
>105 mA 
OFF 
ON 
Probe fault, 
“short”