Application of SECU-DATA 42xM/42xC (4-20 mA)  
4-20 mA
4-20 mA
18-36 V
 DC
Barrier
SECU-BAR 125
18-36 V
 DC
Zone 1
Zone 1
Barrier
SECU-BAR 125
SECU-DATA 420M
SECU-DATA 421M
SECU-DATA 420C
SECU-DATA 421C
 
 
If  SECU-DATA  42xx  is  not  operated  in  an  explosive  area  (Ex-zone  1)  the 
units can be supplied from a standard, not intrinsically safe 24 V DC power 
supply, the barrier SECU-BAR 125 is not required. 
Receiver site: The barrier SECU-BAR 125 for the SECU-DATA 420C/421C 
is required for Ex-zone 1 only. Outside of hazardous areas a SECU-DATA 
1420C/141C without a barrier can be used. 
 
 
Hint: Please, order in addition to the SECU-DATA 42xx set one or two bar-
riers  SECU-DATA  125  (order  no.:  SB125)  according  to  the  Ex-protection 