Maintenance
a) Fuse Replacement
If you have to replace the fuse, ensure that you only use fuses of the specified type and rated current (see “Technical
Data”) as a replacement.
Never repair fuses or bridge the fuse holder.
When replacing the fuse, ensure that the correct fuse value is used according to the device
voltage set (see “Technical Data”).
• Unplug the mains plug from the mains socket and from the mains connection on the device.
• Use a suitable screwdriver to carefully turn out the fuse holder (14) with the defective fuse. For this, slightly press
on the fuse cap and turn it counter-clockwise.
• Remove the defective fuse and replace it with a new fuse of the indicated type.
• Carefully replace the fuse holder (14) with the new fuse in the device. For this, slightly press on the fuse cap and
turn it counter-clockwise until it catches again.
• After this, you can reconnect the device to the mains and take it into operation.
b) Cleaning
Clean the exterior of the device with a soft, dry cloth or brush only.
Never use any aggressive cleaning agents or chemical solutions that may damage the surface of the casing.