Voltage and frequency
The motors are designed for a mains voltage of 380 - 420V, 50 Hz or 420 - 480V, 60
Hz. Motors with an output of up to 2.2 KW inclusive are star connected and from 3.0
KW delta connected. On request, the motors can be supplied for other voltages up to
690V.
Hz. Motors with an output of up to 2.2 KW inclusive are star connected and from 3.0
KW delta connected. On request, the motors can be supplied for other voltages up to
690V.
Output
The nominal motor outputs given in the selection table are intended for constant
operation and a mains connection at nominal voltage and nominal frequency. The
ambient temperature may not exceed 40° C. Certain operating conditions, such as
ambient temperatures above 40° C or installation above 1,000m above sea level as
well as high switching rates, acceleration of large inertias etc. require separate
inquiries and calculations.
operation and a mains connection at nominal voltage and nominal frequency. The
ambient temperature may not exceed 40° C. Certain operating conditions, such as
ambient temperatures above 40° C or installation above 1,000m above sea level as
well as high switching rates, acceleration of large inertias etc. require separate
inquiries and calculations.
Speed
The speeds given in the selection table are achieved at the nominal voltage, nominal
frequency and nominal load.
frequency and nominal load.
Protection system
Motors are designed to the protection system IP 55 (IEC publication 34-5).
Construction type and shape
The motors can be produced in the different basic construction shapes B3 (IM1001),
B5 (IM3001) and up to size 112 also in B14 (IM3601). The construction shapes listed
conform to the IEC regulation 34-7.
B5 (IM3001) and up to size 112 also in B14 (IM3601). The construction shapes listed
conform to the IEC regulation 34-7.
Cooling
The motors are cooled by an external fan covered by a fan cover. Forced ventilation
for frequency-converter duty is possible on request.
for frequency-converter duty is possible on request.
Rotor and shaft
The squirrel cage on all motors is cast from aluminium. Motors in normal design are
supplied with a free shaft end. On request, any motor can likewise be supplied with
two free shaft ends. Motors of all sizes are generally equipped with two equal ball
bearings of the series 62 or 63. From size 200 upwards, it is possible to use roller
bearings in order to achieve higher radial forces.
supplied with a free shaft end. On request, any motor can likewise be supplied with
two free shaft ends. Motors of all sizes are generally equipped with two equal ball
bearings of the series 62 or 63. From size 200 upwards, it is possible to use roller
bearings in order to achieve higher radial forces.
Winding insulation
All motors are insulated to insulation class F. The thermal design of the motors is
made to insulation class B. The motors are suitable for an operation at a frequency-
converter. All motors are ready for Frequency Converter.