User interface 
 
2.8 Menu bar 
LOGO!Soft Comfort Online Help 
Operating Instructions, 06/2014 
121
 
2.8.5.40 
Tools -> Options: Cut Connections 
Here you can choose to cut connections via the Cut/Join (Page 39) either manually or 
automatically.  
You can specify one or both of the following types of connections to be cut: 
●  Connections on import or on upload 
●  Connections routed across a block 
●  Connections exceeding a configurable length 
In the radius text box you can choose either to input the radius points directly or to use the 
scroll bar.  
After confirming these settings, LOGO!Soft Comfort will cut connections accordingly.  
If you configured LOGO!Soft Comfort to cut connections during importing or uploading, the 
software cuts connections according in the following cases: 
●  When you upload (transfer) a circuit program from LOGO! to LOGO!Soft Comfort 
●  When you import (open) a circuit program created with LOGO!Soft Standard or 
LOGO!Soft Comfort 
2.8.5.41 
Tools -> Options: Simulation 
Here you can configure the simulation parameters and its displayed status:  
●  For starting a simulation: 
–  You can choose whether to start the simulation automatically when you switch to 
simulation mode. Otherwise, you must press the green arrow icon   to start 
simulation from simulation mode. 
–  You can choose whether to automatically simulate network communication when the 
IP address is accessible. Otherwise, you must press the icon   to start simulation in 
network. 
–  You can specify whether to reset the status of inputs and outputs at the start of 
simulation. 
●  For interface display: 
–  You can also specify whether to switch the display of signal states and process 
variables on or off in simulation mode. Switching it off improves the performance of 
your simulation because when you disable the display of signal states and process 
variables, there is no need for LOGO!Soft Comfort to calculate these values 
continuously. 
–  In addition, you can specify whether to display a separate simulation window for text 
messages on the LOGO! TD/LOGO! TDE. If selected, simulation mode shows active 
message texts for the LOGO! Base Module and the LOGO! TD/LOGO! TDE in 
separate windows. 
–  You can specify whether to show the elapsed time for simulation in standard 12 hour 
format.