User interface
2.8 Menu bar
LOGO!Soft Comfort Online Help
Operating Instructions, 06/2014
Operating Instructions, 06/2014
121
2.8.5.40
Tools -> Options: Cut Connections
Here you can choose to cut connections via the Cut/Join (Page 39) either manually or
automatically.
You can specify one or both of the following types of connections to be cut:
● Connections on import or on upload
● Connections routed across a block
● Connections exceeding a configurable length
In the radius text box you can choose either to input the radius points directly or to use the
You can specify one or both of the following types of connections to be cut:
● Connections on import or on upload
● Connections routed across a block
● Connections exceeding a configurable length
In the radius text box you can choose either to input the radius points directly or to use the
scroll bar.
After confirming these settings, LOGO!Soft Comfort will cut connections accordingly.
If you configured LOGO!Soft Comfort to cut connections during importing or uploading, the
After confirming these settings, LOGO!Soft Comfort will cut connections accordingly.
If you configured LOGO!Soft Comfort to cut connections during importing or uploading, the
software cuts connections according in the following cases:
● When you upload (transfer) a circuit program from LOGO! to LOGO!Soft Comfort
● When you import (open) a circuit program created with LOGO!Soft Standard or
● When you upload (transfer) a circuit program from LOGO! to LOGO!Soft Comfort
● When you import (open) a circuit program created with LOGO!Soft Standard or
LOGO!Soft Comfort
2.8.5.41
Tools -> Options: Simulation
Here you can configure the simulation parameters and its displayed status:
● For starting a simulation:
● For starting a simulation:
– You can choose whether to start the simulation automatically when you switch to
simulation mode. Otherwise, you must press the green arrow icon to start
simulation from simulation mode.
– You can choose whether to automatically simulate network communication when the
IP address is accessible. Otherwise, you must press the icon to start simulation in
network.
– You can specify whether to reset the status of inputs and outputs at the start of
simulation.
● For interface display:
– You can also specify whether to switch the display of signal states and process
variables on or off in simulation mode. Switching it off improves the performance of
your simulation because when you disable the display of signal states and process
variables, there is no need for LOGO!Soft Comfort to calculate these values
continuously.
– In addition, you can specify whether to display a separate simulation window for text
messages on the LOGO! TD/LOGO! TDE. If selected, simulation mode shows active
message texts for the LOGO! Base Module and the LOGO! TD/LOGO! TDE in
separate windows.
– You can specify whether to show the elapsed time for simulation in standard 12 hour
format.