Tutorial 
 
3.4 Getting started with project creation 
 
LOGO!Soft Comfort Online Help 
156
 
Operating Instructions, 06/2014 
3.4.2.4 
Configuring settings for other standard devices 
For other standard devices 
If you have added SIMATIC HMI devices, SIMATIC S7 devices, a LOGO! TDE, or other 
devices in the network view, you can then edit the device name, IP address, subnet mask, 
and gateway for those devices. You can also browse files on your computer and import a 
project file with the settings for HMI and S7 devices. 
3.4.2.5 
Detecting device online status 
After you configure the online and offline settings, you can go online and view online status 
for the devices. 
Push the devices online to start scanning for any connected LOGO! Base Modules.  
LOGO!Soft Comfort detects all the devices in the project as accessible, inaccessible and 
unknown devices, see "Going online (0BA8 only) (Page 44)" for more information.  
See "Configuring settings for unknown devices (Page 156)" for more information about 
configuring unknown devices.  
After the your device is found, you can stop displaying the online status for all devices. See 
"Going offline (0BA8 only) (Page 45)" for more information. 
3.4.2.6 
Configuring settings for unknown devices 
You can configure the device name, IP address, subnet mask, and gateway of an unknown 
device to define it on the network.  
 
 
Note 
On normal occasions, you are able to delete the connection line between local PC and its 
connected device in the network view by choosing it and clicking the button on the 
standard tool bar. But when deleting the unknown devices and their connection lines, you will 
need to disconnect them physically with the local PC, instead of deleting from the network 
view. 
 
Uploading the added devices 
To upload the added device to a project, right-click the device in the network view and select 
Upload from the shortcut menu. If no previous settings, the uploaded device can use the IP 
address, subnet mask, and gateway you defined in the step above. After completion, the 
device is displayed as an identified LOGO! Base Module.  
 
 
Note 
If the IP address of the uploaded device conflicts with the existing device, a warning 
message of IP address conflict pops out and then you need to reset its IP address according