Tutorial 
 
3.5 Practical example 
 
LOGO!Soft Comfort Online Help 
178
 
Operating Instructions, 06/2014 
UDF Editor 
 
Note that UDF blocks do not support inputs, outputs, analog inputs, analog outputs, M8, 
M25, M26, M27, shift registers, the data log or message text function blocks.  
You have now completed your circuit program. Verify all connections once again and 
configure the block parameters to suit your requirements. 
3.5.10 
Testing the circuit program 
Place your circuit program in simulation mode (Page 95) and verify that your program is 
error-free.   
Although you now know that you can run your circuit program in LOGO!, you still need to 
make sure your circuit program operates as planned. You may also want to modify certain 
parameters. You can try out different input values, test the reaction of the system to power 
failure and compare your calculations or expectations with the simulated reaction of the 
outputs. The simulation toolbar and status window (Page 35) provide the tools you need for 
these tasks. 
The float and pressure switches have a momentary action. If, however, you wish to simulate 
your circuit for testing purposes, simply change the input function from momentary action to 
switching action. 
Example for the FBD Editor: 
 
When you have made all corrections and everything runs as expected, you can start to 
document your circuit program.