Siemens SPS starter kit 6ED1057-3BA00-0AA8 12 Vdc, 24 Vdc 6ED1057-3BA00-0AA8 データシート

製品コード
6ED1057-3BA00-0AA8
ページ / 344
LOGO! functions 
 
4.2 Basic functions list - GF 
 
LOGO! 
120
 
Manual, 06/2014, A5E33039675 
3) Network digital outputs  
The letters NQ identify a network digital output . There are 64 network digital outputs NQ1 to 
NQ64 available for configuration in the circuit program from LOGO!Soft Comfort. 
4) Network analog outputs  
The letters NAQ identify a network analog output. There are 16 network analog outputs 
NAQ1 to NAQ16 available for configuration in the circuit program from LOGO!Soft Comfort. 
4.2 
Basic functions list - GF 
Basic functions represent simple logical elements of Boolean algebra. 
You can invert the inputs of individual basic functions, that is, the circuit program inverts a 
logical "1" at a relevant input to a logical "0"; if "0" is the value at the input, the program sets 
a logical "1". See the programming example at Circuit program input (Page 69). 
The GF list contains the basic function blocks you can use for your circuit program. The 
following basic functions are available: 
 
View in the circuit diagram 
View in LOGO! 
Name of the basic function 
 
 
 
 
(Page 122)  
 
 
(not AND) 
 
 
(Page 123)