LOGO! functions 
 
4.4 Special functions list - SF 
LOGO! 
Manual, 06/2014, A5E33039675 
173
 
4.4.15 
Up/down counter 
Short description 
An input pulse increments or decrements an internal value, depending on the parameter 
setting. The output is set or reset when a configured threshold is reached. The direction of 
count can be changed with a signal at input Dir.  
 
Symbol in LOGO! 
Wiring 
Description 
 
Input R 
A signal at input R resets the internal count value to 
zero. 
Input Cnt 
The function counts the 0 to 1 transitions at input Cnt. 
1 to 0 transitions are not counted. 
You can use the following as the input:  
• 
inputs I3, I4, I5, and I6 for fast counting (only 
LOGO! 12/24RCE/RCEo and LOGO! 
24CE/24CEo): max. 5 kHz, if the fast input is 
directly connected to the up/down counter 
function block 
• 
any other input or circuit component for counting 
low frequency signals (typically 4 Hz) 
Input Dir 
You set the direction of count at input Dir: 
Dir = 0: Count up 
Dir = 1: Count down 
Parameter 
On: on threshold 
 Range of values: 
 0...999999 
Off: off threshold 
 Range of values: 
 0...999999 
StartVal: initial value from which to begin counting 
either down or up. 
Retentivity for internal counter value Cnt: 
/ = No retentivity 
R = The status is retentive. 
Output Q 
Q is set or reset, depending on the current value at 
Cnt and the set thresholds. 
Parameters On and Off 
The actual value of another already-programmed function can provide the on threshold On 
and the off threshold Off. You can use the actual values of the following functions:  
●  Analog comparator (Page 188) (actual value Ax – Ay) 
●  Analog threshold trigger (Page 183) (actual value Ax) 
●  Analog amplifier (Page 195) (actual value Ax) 
●  Analog multiplexer (Page 213) (actual value AQ)