Siemens SPS starter kit 6ED1057-3BA00-0AA8 12 Vdc, 24 Vdc 6ED1057-3BA00-0AA8 データシート

製品コード
6ED1057-3BA00-0AA8
ページ / 344
 
Programming LOGO! 
 
3.7 Writing and starting the circuit program 
LOGO! 
Manual, 06/2014, A5E33039675 
71
 
 
 
Note 
Inputs F1, F2, F3, and F4 correspond to the four function keys on the optional LOGO! TDE. 
More shift register bits (S1.1 to S4.8), blank connectors (X1 to X64) and analog flags (AM1 
to AM64) are available in the 0BA8 device series.  
Network digital inputs (NI1 to NI64), network analog inputs (NAI1 to NAI32), network digital 
outputs (NQ1 to NQ64), and network analog outputs (NAQ1 to NAQ16) are available for the 
0BA8 device series. LOGO! 0BA8 does not include these inputs and outputs until you 
configure them in a circuit program in LOGO!Soft Comfort V8.0 and download the program 
to your LOGO! 0BA8 device. 
 
After selecting I1, the display now shows as follows: 
 
Press OK to confirm. You have now connected I1 to the input of the OR block. 
 
Now you connect input I2 to the input of the OR block: 
1.  Move the cursor to In2: Press   or   
2.  Switch to editing mode: Press OK 
3.  Select the digital input list: Press   or   
4.  Move the cursor to the input number: Press   
5.  Select I2: Press   or   
6.  Apply I2: Press OK 
You have now connected I2 to the second input of the OR block: