Lappkabel Grey 1027708 データシート
製品コード
1027708
U.I. Lapp
GmbH
DATA SHEET
ÖLFLEX
®
CHAIN 808 P
DB 1027700
valid from: 2014-02-21
Originator: KASC / PDC
approved: HAPF / PDC
Document:
DB00127700EN
Page 1 of 1
All rights reserved acc. to DIN ISO 16016.
PD 0019/2.2_11.10EN
Application
ÖLFLEX
CHAIN 808 P cables are high-flexible oil-resistant power and control cables with an outer sheath of Polyurethane
for flexible use and fixed installation under light or medium mechanical load conditions. They are among others designed for
use in dry, damp or wet rooms. Considering the indicated temperature range an outdoor use is possible.
ÖLFLEX
use in dry, damp or wet rooms. Considering the indicated temperature range an outdoor use is possible.
ÖLFLEX
CHAIN 808 P cables are increased oil resistant and at room temperature widely resistant to acids and caustic
solutions. The outer sheath is resistant to high mechanical load, particularly to abrasion and scouring, cut resistant, microbe-
proof and hydrolysis resistant. They are especially suitable for basic requirements (Basic Line)
proof and hydrolysis resistant. They are especially suitable for basic requirements (Basic Line)
in power chains and in per-
manently moved machine parts. Usage of these cables in moving cable carriers or on motor drum guidance or under a ten-
sile strain of more than 15 N/mm
sile strain of more than 15 N/mm
2
conductor cross-section is not allowed.
Application range:
Power chains or moving machine parts, especially in wet areas of machine tools and transfer lines, measuring, control
and regulation circuits, assembly lines, production lines.
Power chains or moving machine parts, especially in wet areas of machine tools and transfer lines, measuring, control
and regulation circuits, assembly lines, production lines.
Design
Design
based on
DIN EN 50525-2-21 resp. VDE 0285-525-2-21 and
DIN EN 50525-2-51 resp. VDE 0285-525-2-51
Conductor
fine wire strands of bare copper acc. to IEC 60228 resp. VDE 0295, Class 5
Core insulation
LAPP special PVC compound P8/1, better than the PVC compound TI2
acc. to DIN EN 50363-3 resp. VDE 0207-363-3
Core identification
acc. to VDE 0293-1, with or without GN/YE protective conductor
black cores with white numbers
acc. to DIN EN 50334 resp. VDE 0293-334
Outer sheath
Polyurethane compound TMPU acc. to EN 50363-10-2 resp. VDE 0207-363-10-2
Colour: grey, similar RAL 7001
Electrical properties
Nominal voltage
U
0
/U:
300/500 V
Test voltage
Core/Core: 4000 V AC
Mechanical and thermal properties
Min. bending radius
flexing up to 3m travel distance (horizontal, self supporting): 10 x cable diameter
flexing up to 10m travel distance (horizontal, sliding): 12 x cable diameter
fixed installation:
4 x cable diameter
Number of bending/unbending
cycles
cycles
2 mio. cycles
Travel distance
10 m
Temperature range
flexing:
-5 °C up to +70 °C max. conductor temp.
fixed installation:
-40 °C up to +80 °C max. conductor temp.
Oil resistance
acc. to EN 50363-10-2 resp. VDE 0207-363-10-2
Tests
acc. to IEC 60811 resp. VDE 0473 part 811, EN 50395, EN 50396
EC Directives
This cable is conform to the EC-Directives 2006/95/EC (Low Voltage Directive)
and 2002/95/EC (RoHS, Restriction of the use of certain hazardous substances).