Lappkabel 0012461, Cable, , Yellow Sheath 0012461 データシート
製品コード
0012461
U.I. Lapp
GmbH
DATA SHEET
ÖLFLEX
®
540 P
DB 0012452
valid from: 2014-03-18
Originator: KASC / PDC
approved: HAPF / PDC
Document:
DB0012452EN
Page 1 of 2
All rights reserved acc. to DIN ISO 16016.
PD 0019/2.2_11.10EN
Application
ÖLFLEX
®
540 P cables are oil-resistant connecting cables with an insulation of TPE and an outer sheath of Polyurethane for
flexible use and fixed installation under increased mechanical load conditions. They are among others designed for use in
dry, damp and wet conditions. Outdoor use: They may only be installed considering the indicated temperature range.
Continuous busy movements, compulsory guidance respectively usage on cable drums or pulleys or under a tensile strain of
more than 15 N/mm² conductor cross-section are not allowed. ÖLFLEX
dry, damp and wet conditions. Outdoor use: They may only be installed considering the indicated temperature range.
Continuous busy movements, compulsory guidance respectively usage on cable drums or pulleys or under a tensile strain of
more than 15 N/mm² conductor cross-section are not allowed. ÖLFLEX
®
540 P cables are increased oil-resistant and at
room temperature widely resistant to acids and caustic solutions. The outer sheath is resistant to high mechanical stress,
particularly to abrasion and scouring, is cut resistant, microbe-proof and hydrolysis resistant. All materials used for these
cables are halogen-free.
Application range:
construction machinery, building sites, camping sites, stage application, agricultural equipment, industrial machinery
particularly to abrasion and scouring, is cut resistant, microbe-proof and hydrolysis resistant. All materials used for these
cables are halogen-free.
Application range:
construction machinery, building sites, camping sites, stage application, agricultural equipment, industrial machinery
Design
Design
based on
EN 50525-2-21 resp. VDE 0285-525-2-21 / HD 22.10 S2 resp. VDE 0282-10
Approvals
up to 1,0 mm²:
VDE Reg.-No. 6583
starting at 1,5 mm²:
VDE Reg.-No. 6584
Conductor
fine wire strands of tinned copper acc. to IEC 60228 resp. VDE 0295, Class 5
Core insulation
Thermoplastic elastomer (TPE)
Core identification
up to 5 cores coloured acc. VDE 0293-308 resp. HD 308 S2
more than 5 cores: black cores with white numbers
with GN/YE ground conductor acc. to DIN EN 50334 resp. VDE 0293-334
Outer sheath
Polyurethane compound TMPU acc. to EN 50363-10-2 resp. VDE 0207-363-10-2
colour: yellow, similar RAL 1016
Electrical properties
Nominal voltage
up to 1,0 mm²:
U
0
/ U 300 / 500 V
starting at 1,5 mm²:
U
0
/ U 450 / 750 V
Test voltage
up to 1,0 mm²:
3000 V AC
starting at 1,5 mm²:
3500 V AC
Mechanical and thermal properties
Min. bending radius
occasional flexing:
10 x outer diameter
fixed installation:
4 x outer diameter
Temperature range
occasional flexing:
-40 °C up to +90 °C max. conductor temperature
fixed installation:
-50 °C up to +90 °C max. conductor temperature
Flammability
flame retardant acc. to IEC 60332-1-2 resp. VDE 0482-332-1-2
Oil resistance
acc. to EN 50363-10-2 resp. VDE 0207-363-10
-2
Halogen-free
acc. to. VDE 0472-815