Proma 108100 110030 COBRITHERM-pro Carrier Plate 108100 110030 データシート

製品コード
108100 110030
ページ / 1
COBRITHERM
®
   
 
 
 
 
   
 
 
 
 
 
 
 
 
 
 
 
 
   
 
 
 
 
 
 
 
 
 
 
DESCRIPTION 
 
Insulated Metal Substrate (IMS), based on thick aluminium and clad with ED copper foil in the other side. It is 
designed for a reliable thermal dissipation circuitry. With a proprietary formulated reinforced-polymer-ceramic 
bonding layer with a high thermal conductivity, dielectric strength, and thermal endurance is guaranteed.  
The material is supplied with a protective film on the aluminium side to protect it against wet PCB process 
ROHS compliance  directive 2002/95/EC 
STANDARD CONSTRUCTIONS 
Aluminium thickness 
1000 - 1500 - 2000 - 3000 
μm 
Aluminium Alloy / Treat 
5052  H18 
Insulation thickness 
110 - 130 
μm 
Dielectric thickness tolerance 
 + 10 
μm  
ED copper thickness 
35 - 70 - 105 - 210 
μm 
 
 
Other constructions available upon request 
 
PROPERTIES 
TEST 
1500 
μm Al / 130 μm dielectric /70 μm Cu 
METHOD 
UNITS 
TYPICAL 
VALUES 
Guaranteed 
values 
Time to blister at 288ºC, floating on solder (50 x 50 mm)  
IEC-61189 
Sec 
>120 
>120 
Copper Peel strength, after heat shock 20 sec/288ºC 
IPC-TM 650-2.4.8 
N/mm 
2,8 
>1,8 
Dielectric breakdown voltage, AC (1) IPC-TM 
650-2.5.6.3
kV 
Proof Test, DC (2) -- 
3000 
3000 
Thermal conductivity (dielectric layer) ASTM-D 
5470 
w/m.ºK 
1,45 
1,45 
Thermal impedance (dielectric layer)   x 10
-3 
ASTM-D 5470 
ºK.m
2
/w 0,089  0,089 
Surface resistance after damp heat and recovery  
IEC-61189 
MΩ 10
5
10
5
Volume resistivity after damp heat and recovery  
IEC-61189 
MΩm 10
4
10
4
Relative permitivity after damp heat and recovery, 10 kHz 
IEC-61189 
- 4,5 4,5 
Dissipation factor after damp heat and recovery 10 kHz 
IEC-61189 
- 0,02 
0,02 
Comparative tracking index (CTI) 
IEC-61112 
600 
600 
Capacitance  
-- 
pF/cm² 
46 
46 
Flammability, according UL-94, class 
UL-94 
class 
V-0 
V-0 
Glass transition temperature of dielectric layer ( by TMA) 
IPC-TM 650-2.4.24 
ºC 
90 
90 
Maximum operating temperature 
-- 
° C 
150 
150 
 
 
DATA 
SHEET 
 
     
 
 
 
 
  
DS_1107
 
 
COBRITHERM   HTC   
 
 
 
 
 
 
 
 
 
 
   
 AISMALIBAR
(1)  Dielectric Breakdown test, is a material destructive laboratory test. It is performed according the IPC-TM-650 part 2.5.6.3., under 
AC voltage, raising it until electric failure, on relative small surface area of the dielectric part, and using metal electrodes. Values 
should be taken as a material reference, and not as guaranteed values. 
(2)  Electrical proof test.  100% of our laminate production delivered, has been “on line” verified at 3000 V
dc
: 500 V/sec. ramp // 5sec. 
held at 2000 V
dc
. 
 
AVAILABILITY 
 
STANDARD SHEET SIZES  mm. 
610 x 440,  920 x 610, 1060 x 585 
Tolerance +5/-0 
mm. 
Squareness 
 3 mm max., as differential between diagonal measurements. 
Standard size tolerance in panels 
 +- 0,3 mm.    
 
The data is based on typical values of standard production and should be considered as general information. Our company reserves the right to future 
changes. It is the responsibility of the user to ensure that the product complies with his requirements. 
 
 
AISMALIBAR, S.A. 
Ctra. de Ripollet, 1, 08110 Montcada i Reixac (BCN) SPAIN 
Tel. +34 93 565 63 00      Fax. +34 93 565 63 27