LogiLink PDA rechargeable battery replaces original battery 170-0737, B520003 3.7 V 1600 mAh 114511 データシート
製品コード
114511
Document NO.:
WI-FHF-CS-PMIIICSL-A
Page 6of 9
MODEL:
CS-PMIIICSL
REV: A/1
discharging less than 42 minutes, cycle life
should be ending.
should be ending.
1C
42
,
,
,
1C
≥
400
8
Vibration Proof Capability
After standard charged, keep for 0.5h~
1h,then installed onto the vibration test with
clamps. Equipment parameters of frequency
and amplitude are as follows(the frequency is to
be varied at the rate of 1oct/min between 10Hz
1h,then installed onto the vibration test with
clamps. Equipment parameters of frequency
and amplitude are as follows(the frequency is to
be varied at the rate of 1oct/min between 10Hz
55Hz, and repeat vibration for 30min. The
battery is to be tested in three mutually
perpendicular directions):
frequency:10Hz 30Hz amplitude: 0.38mm
frequency:30Hz 55Hz amplitude: 0.19mm
perpendicular directions):
frequency:10Hz 30Hz amplitude: 0.38mm
frequency:30Hz 55Hz amplitude: 0.19mm
0.5 1
X Y Z
10Hz 55Hz
30min
1 oct/min:
10Hz 30Hz
0.38mm
30Hz 55Hz
0.19mm
1) Battery appearance should not be
obvious nick, leak, smoke and burst.
2) After test, no defect in electrical
performance, and voltage
≥3.7V.
,
≥3.7V
9
Fall Proof Capability
After complete charge, the battery is to be drop
to a armor plate(18mm 20mm thick) placed on
a cement floor from a height of 1.2 meter for 14
times.(fall down by six sides and one corner).
to a armor plate(18mm 20mm thick) placed on
a cement floor from a height of 1.2 meter for 14
times.(fall down by six sides and one corner).
1.2
18mm
20mm
14
1) Battery should not be leak,
smoke and burst.
2) After test, no defect in electrical
performance, and voltage
≥3.7V.
,
≥3.7V
11
Capacity Retention
1).In environmental temperature 20 ± 5
condition, Use nominal capacity charging
method full charge the battery.
method full charge the battery.
20 ±5
,
2)
Lay the battery opened circuit 28 days, then
use 0.2C discharge it to cut off voltage.
28 ,
0.2C
0.2C discharging time should no less than
90%.
90%.
0.2C
90%
.
1
2
2
Constant Temperature and
Humidity Proof Capability
After standard charged, keep for 0.5h
1h,then Lay the battery in temperature 40±2
and humidity 90% 95% environmental
chambers for
1h,then Lay the battery in temperature 40±2
and humidity 90% 95% environmental
chambers for
60
hours. Then lay the battery in
environmental temperature 20±5 condition for
2 hours. Later discharge it in 0.2C and record
the capacity.
2 hours. Later discharge it in 0.2C and record
the capacity.
0.5
1
40 ±2
90% 95%
60
20 ±5
2h
0.2C
1) Battery appearance should not be
obvious nick, leak, smoke and burst.
2) 0.2C discharging capacity should no
less than 80%.
0.2C
≥
80%