LogiLink PDA rechargeable battery replaces original battery B525350 3.7 V 1100 mAh 117800 データシート
製品コード
117800
Document NO.:
WI-FHF-CS-X50SL-A
Page 7of 9
MODEL:
CS-X50SL
REV: A/1
3.4.
Shipping Voltage (Inspection before shipment): ≥3.7V
(
): ≥3.7V
4.Protection Capability Test Method and Request
Item
Test Method
Request
1
Overcharge Test
Apply a 5V voltage and a 1C charge
current on the battery for
current on the battery for
10
hours.
10
hs
5V
1C
Battery could not be burst, burn, leak and
smoke
smoke
2
Over discharge
Test
Discharge the battery at 1C to cut off
voltage then discharge with loading 30Ω
for 24hs.
voltage then discharge with loading 30Ω
for 24hs.
1C
30Ω
24H
Battery could not be burst, burn, leak and
smoke
.
.
3
Over-current
protection
1) The battery is fully charged to rated
capacity.
2) Load current at 0.2A/S to cut off the
output of the battery.
0.2A/S
,
Battery could not be burst, burn, leak and
smoke
smoke
.
.
4
Pack Short-circuit
Protection
1) The battery is charged to rated
capacity.
2) The battery is to be short-circuited by
connecting the positive and negative
terminals of the battery with
thermocouple having a maximum
resistance load of 0.1Ω for 1h.
terminals of the battery with
thermocouple having a maximum
resistance load of 0.1Ω for 1h.
0.1Ω
1h
Battery could not be burst, burn, leak and
smoke After charging.
smoke After charging.
After charging the battery can be used
normally.
normally.
5. Cell
1) Chem:
Lithium-ion Cell
2) Spec
:
063450AR/3.7V/1100mAh DIKTE
3)
063450AR/3.7V/1100mAh DIKTE