  32  Chapter 6: Manage Storage Space with RAID Groups 
 
 
 
RAID Group Types 
Your Synology NAS supports the following RAID Groups types: 
 
RAID Group for Single Volume or iSCSI LUN (Block-Level) 
  Allocates all available capacity to a single volume or iSCSI LUN (Block-Level). 
  Provides better performance but less storage management flexibility. 
  Allows creation of multiple iSCSI LUNs (Regular File) on volumes. 
  Supports a maximum of one RAID Array. 
  The maximum volume size that can be allocated is 200 TB. 
 
RAID Group for Multiple Volumes or iSCSI LUNs (Block-Level) 
  Supports creating multiple volumes or iSCSI LUNs (Block-Level) on a RAID Group. 
  Provides better storage management flexibility. 
  Allows creation of multiple iSCSI LUNs (Regular File) on volumes. 
  Supports combining multiple RAID Arrays under a RAID Group (when configured as RAID 5 or RAID 6). 
RAID Types 
Depending on the number of available hard disks, you can create RAID Groups using several different RAID 
types. Different RAID types provide different levels of performance, data protection, and storage features. 
Synology NAS supports the following RAID types
1
RAID Type 
HDD # 
Allowed 
Failed HDD # 
Description 
Capacity 
Basic 
Creates a storage space with one hard disk. 
1 x (HDD size) 
JBOD 
2-12 
Combines multiple hard disks into a single, large 
storage space. 
Sum of all HDD 
sizes 
RAID 0 
2-12 
RAID 0 offers Striping, a process of dividing data 
into blocks and spreading the data blocks across 
several hard drives, but without safety measures. 
(HDD #) x 
(Smallest HDD 
size) 
RAID 1 
2-4 
(HDD #) - 1 
Writes a mirrored copy of data to each hard drive, 
providing data redundancy and protection as long 
as one hard disk is operating normally. 
Smallest HDD 
size 
RAID 5 
3-12 per 
RAID Array 
1 HDD within 
each RAID 
Array 
Stripes both data and parity information across all 
member disks, providing data redundancy. If one 
hard disk fails, the system may be rebuilt using 
parity data from other member hard disks 
Supports combining multiple RAID Arrays when 
created on a RAID Group for Multiple Volumes or 
iSCSI LUNs (Block-Level) 
Total capacity of 
combined RAID 
Arrays.  
RAID Array 
capacity = (HDD 
# - 1) x (Capacity 
of smallest HDD). 
RAID 6 
4-12 per 
RAID Array 
2 HDD within 
each RAID 
Array 
RAID 6 provides extra data protection. It uses 
parity mode to store redundant data on space 
equal to the size of two disks for later data 
recovery. 
Supports combining multiple RAID Arrays when 
created on a RAID Group for Multiple Volumes or 
iSCSI LUNs (Block-Level) 
Total capacity of 
combined RAID 
Arrays.  
RAID Array 
capacity = (HDD 
# - 2) x (Capacity 
of smallest HDD) 
RAID 10 
4-12 per 
RAID Array 
(even 
number) 
1 HDD within 
each RAID 1 
group 
Provides the performance of RAID 0 and data 
protection level of RAID 1RAID 10 combines two 
hard drives into a RAID 1 group, and combines all 
the groups with RAID 0. 
(HDD # / 2) x 
(Smallest HDD 
size) 
--------- 
1