[6.ACCIDENTAL RELEASE MEASURES]
___________________________________________________________________________________________________
PERSONAL PREAUTIONS,
: Use mask, goggles and protective gloves.
PROTECTIVE EQUIPMENT AND
Large spills : Remove person to safety.
EMERGENCY PROCEDURE
Ensure adequate ventilation.
Treat from upwind position.
ENVIRONMENTAL PRECAUTIONS
: Do not discharge into the drains, surface waters or ground water directly.
METHODS FOR CLEANING UP
: Prevent dispersion of dust.
Sweep
or
vacuum
by
dust-explosion-proof
type
cleaner.
PREVENTION OF SECONDARY
: No information available
HAZARDS
__________________________________________________________________________________________________
[7.HANDLING AND STORAGE]
___________________________________________________________________________________________________
HANDLING
TECHNICAL MEASURES
: Facilities Storing or utilizing this material should be equipped with an
eyewash
facility
and
a
safety
shower.
PRECAUTIONS
: Avoid inhalation of fine dust .
SAFE HANDLING ADVICE
: Use an adequate ventilation.
Wash
thoroughly
after
handling.
Use
personal
protective
equipment
as
required.
Do
not
breathe
dust/fume/gas/mist/vapours/spray.
Do not eat, drink or smoke when using this product.
This material may cause risk of dust explosion.
STORAGE
SUITABLE STORAGE CONDITIONS
: Keep container tightly closed.
Protect from sun. Store in a well-ventilated room(under 40 ℃)
Store
locked
up.
SAFE PACKAGINH MATERIALS
: No information available
___________________________________________________________________________________________________
[8.EXPOSURE CONTROLS / PERSONAL PROTECTION]
___________________________________________________________________________________________________
ENGINEERING MEASURES
: Facilities storing or utilizing this material should be equipped with an
eyewash
facility
and
a
safety
shower.
Use local exhaust ventilation, in case of generation of dust.
LIMIT
VALUES
ACGIH(TLV)
:
3.5mg/m3
TWA
Carbon
black
TWA 2mg/m3
Paraffin wax fume
10mg/m3
TWA
(inhalable
particles,
recommended);3mg/m3
TWA
(respirable
particles,
recommended)(Particulates
(insoluble
or
poorly
soluble) not otherwise specified (PNOS))
OSHA(PEL)
:
3.5mg/m3
TWA
Carbon black
15mg/m3
TWA
(total
dust);5mg/m3 TWA(respirable fraction)