Fluke 190-202/S 2-channel hand-held oscilloscope, ScopeMeter® 190 series II, hand-held 4025554 データシート

製品コード
4025554
ページ / 8
2  Fluke Corporation     ScopeMeter 190 Series II
2  Fluke Corporation     ScopeMeter 190 Series II
Oscilloscope Modes
190-062
190-102
190-202
190-104
190-204
Vertical deflection
Number of channels
2
2
2
4
4
Bandwidth
60 MHz
100 MHz
200 MHz
100 MHz
200 MHz
Rise time
5.8 ns
3.5 ns
1.7 ns
3.5 ns
1.7 ns
Number of scope inputs
2 input channels plus external trigger
4 input channels
Channel architecture
All inputs fully insulated from each other and from ground 
Inputs may be activated in any combination
Input coupling
AC or DC, with ground level indicator
Input sensitivity
2 mV/div to 100 V/div, plus variable attenuation
Bandwidth limiter
User selectable: 20 kHz, 20 MHz or full bandwidth
Normal/invert/variable
On each input channel, switched separately
Input voltage
CAT III 1000 V/CAT IV 600 V rated, see General Specifications for further details
Vertical resolution
8 bit 
Accuracy
± (2.1 % of reading + 0.04 x range/div) @ 5 mV/div to 100 V/div
Input impedance
1 MΩ ± 1 % // 14 pF ± 2 pF
Horizontal
Maximum real-time sample rate 
(sampled simultaneously)
625 MS/s for each 
channel
1.25 GS/s for each 
channel
2.5 GS/s (2ch)
1.25 GS/s for each 
channel
2.5 GS/s (2ch)  
1.25 GS/s (4ch)
Record length
Up to 10,000 samples per channel
Time base range
10 ns/div  
to 4 s/div
5 ns/div  
to 4 s/div
2 ns/div  
to 4 s/div
5 ns/div  
to 4 s/div
2 ns/div  
to 4 s/div
Time base in a 1-2-4-sequence 
Slower time/division settings using ScopeRecord
 Roll mode (see ‘Recorder mode’)
Maximum record length
10,000 samples per channel in scope mode;  
30,000 points per channel in ScopeRecord
 Roll mode (see ‘Recorder mode’)
Timing accuracy
± (0.01 % of reading + 1 pixel)
Glitch capture
8 ns peak detect on each channel  
(using real time sampling and data compression, at any timebase setting)
Display and acquisition
Display
153 mm (6 in) full-color LCD with LED backlight
Display modes
Any combination of channels; average on/off; replay
Visible screen width
12 divisions horizontally in scope mode
Digital persistence modes
off/short/medium/long/infinite and envelope mode
Waveform mathematics
One mathematical operation on any 2 input channels: add/subtract/multiply; X-Y-mode 
Frequency Spectrum using FFT analysis
Acquisition modes
Normal, Averaged, Auto, Single Shot, ScopeRecord™ roll, glitch capture,  
waveform compare with automatic “Pass/Fail testing”; Replay
Trigger and delay
Source
Input A, B or External (via meter input)
Input A, B, C or D
Modes
Automatic Connect-and-View
, free run, single shot, edge, delay, dual slope,  
video, video line, selectable pulsewidth (channel A only), N-cycle
Connect-and-View
Advanced automatic triggering that recognizes signal patterns, automatically sets up and continuously 
adjusts triggering, time base and amplitude 
Automatically displays stable waveforms of complex and dynamic signals like  
motor drive and control signals 
Can be switched off if preferred
Video triggering (on ch. A)
NTSC, PAL, PAL+, SECAM; Includes field 1, field 2 and line select
High-res, non-interlaced video
Non-interlaced video with line-select, for line frequencies in the range 14 kHz up to 65 kHz
Pulse width triggering 
(on channel A)
Pulse width qualified by time 
Allows for triggering <t, >t, =t, ≠ t, where t is selectable in minimum steps of 0.01 div or 50 ns
Time delay
1 full screen of pre-trigger view or up to 100 screens  
(=1,200 divisions) of post-trigger delay
Dual slope triggering
Triggers on both rising and falling edges alike
N-cycle triggering
Triggers on N-th occurrence of a trigger event; N to be set in the range 2 to 99