Behringer Xenyx 1204 USB Mixer XENYX 1204 USB データシート

製品コード
XENYX 1204 USB
ページ / 13
9
XENYX 1204/1204FX
+48 V
The red “+48 V” LED lights up when the phantom power supply
is  switched  on.  The  phantom  power  supply  is  necessary  for
condenser  microphones  and  is  activated  using  the  switch  on
the rear of the device.
+
Please  do  not  connect  microphones  to  the  mixer
(or  the  stagebox/wallbox)  while  the  phantom
power  supply  is  switched  on.  Connect  micro-
phones  before  you  switch  on  the  power  supply.
In  addition,  the  monitor/PA  loudspeakers  should
be  muted  before  you  activate  the  phantom  power
supply.  After  switching  on,  wait  approx.  one  minute
to  allow  for  system  stabilization.
LEVEL METER
The  high-precision  level  meter  accurately  displays  the
appropriate signal level.
LEVEL SETTING:
When recording to a digital device, the recorder’s peak meter
should not exceed 0 dB. This is because, unlike analog recordings,
slightly excessive levels can create unpleasant digital distortion.
When  recording  to  an  analog  device,  the  VU  meters  of  the
recording  machine  should  reach  approx.  +3  dB  with  low-
frequency signals (e.g. kick drum). Due to their inertia VU meters
tend to display too low a signal level at frequencies above 1 kHz.
This is why, for example, a Hi-Hat should only be driven as far
as -10 dB. Snare drums should be driven to approx. 0 dB.
+
The  peak  meters  of  your  XENYX  display  the  level
virtually  independent  of  frequency.  A  recording  level
of  0  dB  is  recommended  for  all  signal  types.
MODE (1204FX only)
The  MODE  switch  determines  whether  the  channels’  SOLO
switch operates as PFL (Pre Fader Listen) or as solo (Solo In
Place).
PFL
To activate the PFL function, depress the MODE switch. The
PFL function should, as a rule, be used for gain setting purposes.
The signal is sourced pre-fader and assigned to the mono PFL
bus.  In  the  “PFL”  setting,  only  the  left  side  of  the  peak  meter
operates. Drive the individual channels to the 0 dB mark of the
VU meter.
Solo
When the MODE switch is not depressed, the stereo solo bus
is active. Solo is short for “Solo In Place”. This is the customary
method for listening to an individual signal or to a group of signals.
As soon as a solo switch is pressed, all channels in the control
room (and headphones) that have not been selected are muted
thereby  retaining  stereo  panning.  The  solo  bus  can  carry  the
output signals of the channel pan controls, the aux sends and
the stereo line inputs. The solo bus is, as a rule, switched post-
fader.
+
The  PAN  control  in  the  channel  strip  offers  a
constant  power  characteristic.  This  means  that  the
signal  is  always  at  a  constant  level,  irrespective  of
its  position  in  the  stereo  panorama.  If  the  PAN
control  is  moved  fully  left  or  right  from  center,  the
level  increases  by  4  dB  in  that  channel.  This
ensures  that,  when  set  in  the  center,  the  audio
signal  is  not  louder.  For  this  reason,  with  the  solo
function  activated  (Solo  in  Place),  audio  signals
from  the  channels  with  PAN  controls  that  have  not
been  moved  fully  to  the  left  or  right  are  displayed
at  a  lower  volume  than  in  the  PFL  function.
As  a  rule,  solo  signals  are  monitored  via  the  control  room
outputs  and  headphones  connector  and  are  displayed  by  the
level  meters.  If  a  solo  switch  is  pressed,  the  signals  from  the
tape  input,  Alt  3-4  and  main  mix  are  blocked  from  the  control
room outputs, the headphone connector and the level meter.
MAIN SOLO (1204FX only)
The MAIN SOLO LED lights up as soon as a channel or aux
send solo switch is pressed. The MODE switch also has to be
set at “Solo”.
PFL (1204FX only)
The PFL LED indicates that the peak meter is set to PFL mode.
Fig.  2.12:  PHONES  connector
PHONES
You can connect headphones to this 1/4" TRS connector. The
signal on the PHONES connection is sourced from the control
room output.
2.3.7 Alt 3-4 and main mix fader
Fig. 2.13: Alt 3-4 and main mix fader
Use the high-precision quality faders to control the output level
of the Alt 3-4 subgroup and main mix.
2.4 Rear view of 1204FX/
1204
2.4.1 Main mix outputs, Alt 3-4 outputs and
control room outputs
Fig. 2.14: Main mix outputs, Alt 3-4 outputs and
control  room  outputs
MAIN OUTPUTS
The  MAIN  outputs  carry  the  MAIN  MIX  signal  and  are  on
balanced XLR connectors with a nominal level of +4 dBu.
ALT 3-4 OUTPUTS
The ALT 3-4 outputs are unbalanced and carry the signals of
the  channels  that  you  have  assigned  to  this  group  using  the
MUTE switch. This can be used to route a subgroup to a further
mixing console for example, or or it could be used as a recording
output working in tandem with the main output. This means you
could  record  to  four  tracks  simultaneously.  The  icing  on  the
cake, so to speak, is that you could connect Y-cables to these
four outputs and then connect your 8-track recorder in such a
way that you have 2 x 4 tracks (e.g. channel 1 feeds track 1 and
track 2, etc.). In the first recording pass, you record on tracks 1,
2. CONTROL ELEMENTS AND CONNECTORS