XENYX QX2442USB/QX2222USB/QX1832USB/QX1622USB User Manual
5.5  Voltage supply, phantom power supply 
and fuse
All Models
Fig. 5.6: Voltage supply and fuse
FUSE HOLDER/IEC MAINS RECEPTACLE
The console is connected to the mains via the cable supplied, which meets the 
required safety standards. Blown fuses must only be replaced by fuses of the 
same type and rating. The mains connection is made via a cable with IEC mains 
connector. An appropriate mains cable is supplied with the equipment.
POWER switch
Use the POWER switch to turn on the mixing console. The POWER switch should 
always be in the “Off” position when you are about to connect your unit to 
the mains.
To disconnect the unit from the mains, pull out the main cord plug. 
When installing the product, ensure that the plug is easily accessible. If mounting 
in a rack, ensure that the mains can be easily disconnected by a plug pull or by an 
all-pole disconnect switch on or near the rack.
◊ 
Attention: The POWER switch does not fully disconnect the unit from 
the mains. Unplug the power cord completely when the unit is not used 
for prolonged periods of time.
PHANTOM switch
The PHANTOM switch activates the phantom power (necessary to operate 
condenser microphones) on the XLR sockets. The red +48 V LED illuminates 
when phantom power is on. As a rule, dynamic microphones can still be used 
with phantom power, provided that they are wired in a balanced configuration. 
In case of doubt, contact the microphone manufacturer!
◊ 
Connect microphones before you switch on the phantom power supply. 
Please do not connect microphones to the mixer (or the stagebox/
wallbox) while the phantom power supply is switched on. In addition, 
the monitor/PA loudspeakers should be muted before you activate the 
phantom power supply. After switching on, wait approx. one minute to 
allow for system stabilization.
6.  Installation
6.1  Cable connections
You will need a large number of cables for the various connections of the console. 
The illustrations below show the wiring of these cables. Be sure to use only 
high-grade cables.
strain relief clamp
sleeve
tip
sleeve
pole 1/ground
tip
pole 2
The footswitch connects both poles momentarily
¼" TS footswitch connector
Fig. 6.1: Foot switch connector
6.1.1  Audio connections
Please use commercial RCA cables to wire the 2-track inputs and outputs.
You can, of course, also connect unbalanced devices to the balanced input/
outputs. Use either mono plugs, or use stereo plugs to link the ring and shaft 
(or pins 1 & 3 in the case of XLR connectors).
output
For unbalanced use, pin 1 and pin 3 
have to be bridged
1 = ground/shield
2 = hot (+ve)
3 = cold (-ve)
input
1
2
3
1
2
3
Balanced use with XLR connectors
Fig. 6.2: XLR connections
◊ 
Caution! You must never use unbalanced XLR connectors (PIN 1 and 
3 connected) at the MIC input jacks if you want to use the phantom 
power supply.