83 
 
The following actions cause the BMC to generate an NMI pulse: 
•  Receiving a Chassis Control command to pulse the diagnostic interrupt. This 
command does not cause an event to be logged in the SEL. 
•  Watchdog timer pre-timeout expiration with NMI/diagnostic interrupt pre-timeout 
action enabled. 
 
The following table describes behavior regarding NMI signal generation and event logging by 
the BMC. 
 
Table 28. NMI Signal Generation and Event Logging 
Casual Event 
NMI 
Signal 
Generation 
Front Panel Diag Interrupt Sensor Event Logging 
Support 
Chassis Control command (pulse diagnostic 
interrupt) 
– 
Front panel diagnostic interrupt button pressed 
Watchdog Timer pre-timeout expiration with 
NMI/diagnostic interrupt action 
 
8.3.1.5 
NIC Activity LED Support 
The Front Control Panel includes an activity LED indicator for each on-board Network Interface 
Controller (NIC). When a network link is detected, the LED will turn on solid. The LED will blink 
once network activity occurs at a rate that is consistent with the amount of network activity that 
is occurring. 
8.3.1.6 
Hard Drive Activity LED Support 
The drive activity LED on the front panel indicates drive activity from the on-board hard disk 
controllers. The server board also provides a header giving access to this LED for add-in 
controllers. 
 
8.3.1.7 
System Status LED Support 
The System Status LED is a bi-color (Green/Amber) indicator that shows the current health of 
the server system. The system provides two locations for this feature; one is located on the 
Front Control Panel, the other is located on the back edge of the server board, viewable from 
the back of the system. Both LEDs are tied together and will show the same state. The System 
Status LED states are driven by the on-board platform management sub-system. 
 
8.3.2 
Front Panel USB Connector 
The server board includes two 10-pin connector, that when cabled, can provide up to two USB 
ports to a front panel respectively. On the server board the connectors are labeled “USB_4-5” 
and “USB_6-7”. The following table provides the connector pin-out.