EZ800/EZD Control Commands
MN05013001E
114
Value (hex), sent by
Master
Slave
0
Toggle byte
J
page 94
1
Command: Read
91
Response:
Read successful
C2
Command 
rejected
C0
2
Len
04
04
3
Type
For RN1 – RN32: 08
For SN1 – SN32: 0A
4
Index
01 – 08
1
01 – 08
1
5 – 8
Data 1 – 4
00
J
Table 50
1) Corresponds to NET-ID
Reading receive data network RN1 .. RN32/send data 
network SN1 .. SN32
EZ-NET allows a point-to-point connection to be implemented 
between the individual NET stations. The RN and SN data are 
used for the data exchange (see the EZ800 manual and EZD 
manual).
The latest editions of these manuals are available as PDF files 
from the Internet at: 
EZ800 manual 
search term: MN05013004E. EZD manual search term: 
MN05013005E.
J
The RN SN data of the local device (Index = 0) to which the 
EZ204-DP is fitted cannot be scanned. In this case the 
command would be denied with the 0C
hex
 signal.
Byte
Meaning