Eaton Electrical PROFIBUS-DP EZ204-DP ユーザーズマニュアル

ページ / 212
For more information visit: www.EatonElectrical.com
EZ800/EZD Control Commands
MN05013001E
136
High-speed counters CH01 .. CH04
Telegram structure
Byte
Meaning
Value (hex), sent by
Master
Slave
0
Toggle byte
J
page 94
1
Command: 
Read
92
Write
B2
Response:
Read successful
C2
Write successful
C1
Command 
rejected
C0
2
Type
16
16
3
Instance
01 – 04
01 – 04
4
Index
J
Table 71
J
Table 71
5 – 8
Data 1 – 4
Read operation
00
depending on 
index, 
J
Table 72
Write operation
depending on 
index,
J
Table 72
00