EZ800/EZD Control Commands
MN05013001E
168
Send network data function blocks PT01 .. PT32
Telegram structure
Table 104: Operand overview
Byte
Meaning
Value (hex), sent by
Master
Slave
0
Toggle byte
J
page 94
1
Command: Read
92
Response:
Read successful
C2
Command 
rejected
C0
2
Type
1F
1F
3
Instance
01 – 20
01 – 20
4
Index
J
Table 104
5 – 8
Data 1 – 4
00
depending on 
index, 
J
Table 105
Index 
(hex)
Operand
Read
Write
00
Bit IO, J Table 105
×
01
Mode/Parameter
02
Input value: Setpoint that 
it transmitted to the NET 
network
I1
×
J
The data for index 2 is transferred as a 32-bit value in Intel 
format (Data 1 – Low Byte to Data 4 – High Byte).