Schumacher PID-200 ユーザーズマニュアル

ページ / 12
10
PROBLEM: Keeps Blowing Fuses
Reason/Solution
1.  Fuse may be rated too low.
2.  Check auxiliary socket for debris or short.
3.  May be bad unit.
  Try unit in another socket.
SPECIFICATIONS
Maximum Continuous Power ............................. 200 Watts
Surge Capacity (Output Wattage) ...................... 400 Watts
No Load Current Draw ...................................... <.36 Amps
Wave Form ......................................... Modified Sine Wave
Input Voltage Range.................................... 11 – 15.5V DC
Low Battery Alarm .................................. 10.7V – 11.3V DC
Output Voltage ......................................... 110V – 125V AC
Low Battery Shutdown ...........................10.2V – 10.8V DC 
High Battery Shutdown ..........................15.0V – 16.0V DC
Optimum Efficiency ........................................... >90% max 
AC Outlets ......................................One, 110V AC 3-Prong
USB Port ......................................................................One
36" Cable with 12 Volt Accessory Plug ........................One
Fuse ............................................................... One, 25 Amp