Meridian Data SecurStor iSCSI to SATA-II RAID Subsystem 16i ユーザーズマニュアル
Chapter 5: Subsystem Maintenance and Upgrading
5-7
5.3.3 DIMM
Module
Installation
WARNING!
The pre-installed modules must be removed prior to installing new modules. Do this
with care. Sensitive components can be damaged during the process.
Step 1.
Prepare an anti-static work pad or container for placing a removed
module. Use of an ESD grounding strap is highly recommended.
Step 2.
Remove the BBU module, if installed. Carefully place the module for
it contains Li-ion batteries. Do not drop it to the floor or place it near
any heat source or fire.
Step 3.
Remove the controller module. See Section 0.
Step 4.
Remove the previously installed DIMM module from the DIMM
socket. To do this, push the white module clips on either side of the
DIMM socket down. By doing this, the previously installed modules
will be ejected from the DIMM socket. (See Figure 5-4)
Figure 5-4: Removing a DIMM Module
Step 5.
Gently pull the DIMM module out of the DIMM socket.
Step 6.
Insert the replacement module into the DIMM socket. Make sure the
white clips of the DIMM socket are in the open positions. Align the
DIMM module with the DIMM socket by checking its “keyed”