Kentrox AI296 ユーザーズマニュアル

ページ / 404
AI296 Version 9.8x User’s Guide
Link Configuration: Virtual Circuit Configuration
6-88
2. Enter a value (
02
 through 
15
) associated with the PVC to be configured. Menu 
4.2.11.12.9.2.1 (the PVC Edit Menu) appears.
3. For 
01*PVC Type
, enter 
1
 to select 
Passive
Active
, or 
Connect on activity
. The default 
is 
Passive
.
4. For 
02 LCN Low
, enter 
2,
 and the minimum LCN value. Valid values are 
1
 to 
1024
The default is 
1
.

Note: An asterisk (
*
) configures all LCNs for the link with values defined in menu 
item 4.2.1114.12.9.1.
5. For 
03 LCN High
, enter 
3,
 and the maximum LCN value. Valid values are 
1
 to 
1024
The default is 
1
.
6. For 
04 RESET Timer Interval
, enter 
4,
 and the reset timer interval value.
The timer type, range, and default settings depend on the PVC type. Refer to 
 for PVC types, timer types, ranges, and defaults.
>3
                                                           Menu 4.2.11.12.9.2.1
01*PVC Type (Passive, Active, Connect on activity)----------------------Passive
02 LCN Low (* for all LCNs for the link)-----------------------------------0001
03 LCN High----------------------------------------------------------------0001
04 RESET Timer Interval (seconds)-----------------------------------------00000
20 Save the changes made
21 Exit this menu with no changes
Enter item number and optional ",value" then push <CR> key
>
Table 6-1   PVC and Timer Type
PVC Type
Timer Type
Range
Default
Active
Call Timer
30 to 600 s
30 s
Connect on Activity
Inactivity Timer
1 to 600 s
1 s