Honeywell HEGS5001 ユーザーズマニュアル

ページ / 68
5.2.5  Programming a VectorScan 
Note:  VectorScan Programming is only available to Master users. 
1. Press 
the 
Dome Menu (
1. ___
3. ___
) key. 
2. Press 
the 
+ or – key until VectorScan Menu is displayed. 
3. Press 
the 
Enter (
) key. 
5. Press 
the 
+ or – key until Program is displayed. 
6. Press 
the 
Enter (
) key.  Follow the on-screen prompts that appear on the monitor 
where the KD6/HD6 video is viewed. 
<                Select Function            >
 
7.  Enter the VectorScan number (0-9) using the numeric keypad and press the Enter 
(
) key.  If the selected VectorScan# has already been programmed the title is 
displayed and the programmed PreShots are displayed.  To accept the existing title, 
press Enter (
).  To change the current title proceed to step 8. 
8.  Enter the desired title by performing the following steps. 
a. Press 
the 
+ or – key until the desired character is displayed on the LCD screen, 
and then press Character Select (
ABC
).  The controller sends the character to 
the KD6/HD6. 
b.  Continue selecting characters and press Character Select (
ABC
) until the 
desired title is displayed on the monitor. 
c. Press 
Enter (
).   The cursor moves to the first PreShot field. 
9.  Enter the first PreShot Number (0-99) using the numeric keys.  Note:  If the cursor 
doesn’t automatically move to the Velocity field, press the right arrow key („) below 
the controller’s LCD. 
10.  Enter the velocity from 1 to 400 (degrees per second) in the VELOCITY column of 
the 0 row.  If the cursor doesn’t automatically move to the Velocity field, press the 
right arrow key („) below the controller’s LCD. 
11.  Type the dwell time from 0-99 seconds. 
12.  Continue entering PreShots (up to a total of 64) by repeating steps 9, 10, and 11. 
Rev. 1.01 
30 900.0800 
  
19-Jun-06