COMBUSTION AIR SUPPLY 
For a mobile home installation the stove must be 
connected to an outside source of combustion air. A 2” 
inside diameter metallic pipe, either flexible or rigid, may 
be attached to the inlet at the stove’s rear (refer to figure 
4).  A rodent guard (minimum ¼” wire mesh)/wind hood 
must be used at the terminus (refer to figure 5). All 
connections must be secured and airtight by either using 
the appropriately sized hose clamp and/or UL-181-AP 
foil tape.  
For mobile home installations only: 2” inside diameter 
pipe may be used for the first 5 feet of combustion air 
supply run. From 5 to 10 feet use 2 ¾” inside diameter 
pipe. No combustion air supply may exceed 10 feet. 
Sources of Outside Combustion Air 
a. 
In fireplaces 
 
Chimney top. 
 
Ash clean out door. 
b. 
For freestanding installations 
 
A hole in floor near stove rear terminating only 
in a ventilated crawl space. 
 
A hole in the wall behind the stove. 
WHEN OUTSIDE AIR IS NOT USED 
If outside air is not used, it is important that combustion 
air is easily available to the air inlet. A closeable outside 
air register can be used in tightly insulated homes. 
VENTING 
The Breckwell P2700 is certified for use with listed 
TYPE L-Vent, 3” or 4” diameter in size. The stove was 
tested with Simpson Duravent brand. Class “A” chimney 
is not required. Refer to the instructions provided by the 
vent manufacturer, especially when passing through a 
wall, ceiling or roof. 
This is a pressurized exhaust system. All vent connector 
joints must be sealed with 500
°
F (260
°
C) RTV silicone 
sealant to ensure consistent performance and avoid 
smoke spillage. All horizontal connector joints must be 
sealed with UL-181-AP foil tape. We recommend that all 
vertical vent connector joints be secured with a minimum 
of 3 screws. 
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE 
SERVING ANOTHER APPLIANCE. 
DO NOT INSTALL A FLUE DAMPER IN THE 
EXHAUST VENTING SYSTEM OF THIS UNIT. 
INSTALL VENT AT CLEARANCES SPECIFIED BY 
THE VENT MANUFACTURER. 
 
 
 
 
 
 
 
 
 
 
 
 
INSTALLATION 
FIGURE 4 
FIGURE 5 
INSTALLATION