Western Digital Sentinel RX4100 Small Business Storage Server WDBLVH0120KBK ユーザーズマニュアル

ページ / 117
APPENDIX
102
WD SENTINEL RX4100
ADMINISTRATOR AND MAINTENANCE GUIDE
Replacing a Server Fan
When a fan requires replacement, you will receive an e-mail Alert indicating that there is a
problem with one of your WD Sentinel server fans.
The fans in the WD Sentinel server are “cold swappable.” This means that the WD Sentinel
server must be shut down prior to your fan replacement. To shut down your WD Sentinel
server, follow the steps outline in “Shutting Down the Server” on page 45.
What you’ll Need:
Phillips screwdriver
Replacement server fan
Replacing a Server Fan
1.
Shut down the server.
2.
Disconnect all external connections, keeping the power cord plugged in.
3.
Follow the steps outlined in “Removing the Unit Cover” on page 98.
4.
Locate the fan that needs to be replaced (Figure 10). An LED identifies the failed fan.
Figure 10. Locate fan
5.
Carefully disconnect the fan interface connector and remove the fan from the unit
(Figure 11).
Figure 11. Remove fan