Blodgett 30048SB プリント

ページ / 2
BLODGETT
www.blodgett.com
1100 Old Honeycutt Road  Fuquay-Varina, NC 27526  USA • Phone: (877) 255-3976 • Fax: (866) 644-1354
Printed in U.S.A.
NOTE: FOR COMMERCIAL USE ONLY
APPROVAL/STAMP
P/N BR00040 Rev A (1/08)
FREEZER W/SELF-CONTAINED
CONDENSER
SHORT FORM SPECIFICATIONS
The item shall be freezer base-section for a sectional range. Unit shall a have 430 stainless steel #3 polish top, front, sides, back, drawers and interior cavity. The item shall have draw-
ers that hold standard sized (12” x  20” x  4”) pans (not included). The drawer assemblies shall be removable for cleaning. The unit shall include a 6’ (152cm) power cord with grounded
plug to receive 50 or 60hz, single phase, 120VAC electric power. The unit shall have a self contained condenser. The unit shall be at most 32-1/2” deep and shall be 26” high including
adjustable 6” legs. Refrigerant is CFC-free R-404a. Provide options and accessories as indicated.
NOTE: The company reserves the right to make substitutions of components without prior notice
DIMENSIONS ARE IN INCHES (MM).
Model 30084SB
84 (2134)
Model 30036SB
36 (914)
Model 30060SB
60 (1524)
96 (2438)
Model 30096SB
Model 30108SB
108 (2743)
Model 30072SB
72 (1829)
Model 30048SB
48 (1219)
Model 30120SB
120 (3048)
32-1/2 (826)*
Power
Cord
26
(660)
6 (152)
Condensate
Drain Tube
RIGHT SIDE
REAR VIEW
Minimum clearance on all sides is 3” (76mm). However, modular
range-top sections can be mounted directly on top using an
insulated base adapter. Also, these refrigerated bases can be
part of a sectional battery provided that the adjoining base
sections are insulated (or do not produce heat).
SHIPPING INFORMATION
Approximate weight:
30036SB
340 lbs (154 kg)
30048SB
410 lbs (186 kg)
30060SB
550 lbs (249 kg)
30072SB
650 lbs (295 kg)
30084SB
745 lbs (338 kg)
30096SB
855 lbs (388 kg)
30108SB
960 lbs (435 kg)
30120SB
1075 lbs (488 kg)
OTHER TECHNICAL INFORMATION
Avoid locating where the temperature will drop below 55
°
F
(13
°
C) or rise above 90
°
F (32
°
C).
Check local codes for fire and sanitary regulations.
Model
Width
Cooled Volume
ft
(m
3
)
Cooling Capacity
BTU/hr
Electricity
120V amps
Recommended
Compressor
30036SB
36”
4 (0.11)
1450
8
1/3 H.P.
30048SB
48”
6.7 (0.19)
1670
8
1/3 H.P.
30060SB
60”
10 (0.28)
1802
8
1/3 H.P.
30072SB
72”
13 (0.37)
1875
10.1
1/2 H.P.
30084SB
84”
16 (0.45)
1920
10.1
1/2 H.P.
30096SB
96”
18 (0.51)
1955
20
3/4 H.P.
30108SB
108”
22 (0.62)
1955
20
3/4 H.P.
30120SB
120”
25.5 (0.72)
2000
20
3/4 H.P.
TECHNICAL INFORMATION