Bunn 10690 ユーザーズマニュアル

ページ / 17
Page 11
SET/LOCK SWITCH
THERMOSTAT KNOB
FIG 11-1
LOCK
SET
-1000
213.8
101.0
200
93.3
-500
212.9
100.5
200
93.3
0
212.0
100.0
200
93.3
500
211.1
99.5
200
93.3
1000
210.2
99.0
200
93.3
1500
209.3
98.5
200
93.3
2000
208.4
98.0
200
93.3
2500
207.4
97.4
200
93.3
3000
206.5
96.9
199
92.8
3500
205.6
96.4
198
92.2
4000
204.7
95.9
197
91.7
4500
203.8
95.4
196
91.1
5000
202.9
94.9
195
90.6
5500
201.9
94.4
195
90.6
6000
201.0
93.9
194
90.0
6500
200.1
93.4
193
89.4
7000
199.2
92.9
192
88.9
7500
198.3
92.4
191
88.3
8000
197.4
91.9
190
87.8
8500
196.5
91.4
189
87.2
9000
195.5
90.8
188
86.7
9500
194.6
90.3
187
86.1
10000
193.7
89.8
186
85.6
Brew water temperature is factory set at 200
° F (93.3° C)
Areas of high altitude will require lowering this tempera-
ture to prevent boiling.  This chart should be used as a
guide when readjusting the brew water temperature.
Altitude
(Feet)
Boiling point
of water
° F          ° C
Recommended
water temperature
° F          ° C
NOTICE
35665.0000A  05/04  © 2004  Bunn-O-Matic Corporation
THERMOSTAT
In most locations the thermostat should be turned to the full clockwise postion (200° F) for optimum brewing 
temperature. In areas of high altitude you may have to turn it down (counterclockwise) to prevent boiling.
41721 080310
the switch is pressed, two seconds are added to the brew time period.  Allow the brew cycle to finish in order to 
verify that the desired volume has been achieved.
 
To decrease a batch size, Press and release the START or BREW switch once for every two-second interval 
to be removed from the total brew time period; then immediately press and hold down the START or BREW 
switch until three clicks are heard. Release the switch. (Failure to release the switch within two seconds after the 
third click causes the volume setting to be aborted and previous volume setting will remain in memory). Allow 
the brew cycle to finish in order to verify that the desired volume has been achieved.
2.  Setting batch sizes. To set a batch volume, first check that the SET/LOCK switch is in the “SET” position on 
the circuit board. Press and hold the START or BREW switch until three distinct clicks are heard (this will take 
approximately ten seconds), and then release the switch. (Failure to release the switch within two seconds after 
the third click causes the volume setting to be aborted and previous volume setting will remain in memory). View 
the level of the liquid being dispensed. When the desired level is reached, turn the ON/OFF switch to “OFF”. The 
brewer remembers this volume and will continue to brew batches of this size until the volume setting procedure 
is repeated. Empty server(s), turn selector switch to positions that have yet to be set, and repeat batch setting 
procedure until all batch sizes are set. 
NOTE: When brewing coffee, batch volumes will decrease due to absorption by the coffee grounds.
3.  Setting programming disable feature. If it becomes necessary to prevent anyone from changing brew times 
once programmed, you can set the SET/LOCK switch to the “LOCK” position. This will prevent any programming 
to be done.
NOTE: If the clicks can not be heard, lightly grip  the incoming water line to feel when the valve cycles on 
and off.
DUAL VOLT SWITCH