TROUBLESHOOTING 
  
 SYMPTOM 
  
PROBABLE CAUSE 
  
REMEDY 
D1 Nothing Works 
  Hydraulic Circuit Not Complete 
     
  
 
1. Hydraulic Valve not engaged 
1. Engage valve to full detent 
  
 
2. 1 or more quick couplers not 
2. Fully engage all couplers 
  
  
   completely engaged. 
    
  
 
3. Defective quick coupler 
3. Replace defective quick couplers 
  
  
4. Hydraulic pump low on fluid 
4. Top up fluid level 
D2 Auger Rotates 
   Hydraulic Circuit Reversed 
     
  
backwards, and 
1. Main valve is in reverse 
1. Reverse valve direction or 
  
fan does not 
2. Quick couplers are connected 
2. Switch hose connections to 
  
rotate 
   backwards. 
  the machine. 
D3 Fan turns too 
1. Inadequate hydraulic flow for 
1. Check the gpm of your  
  
slow 
  this motor size. 
  system. 
  
  
2. Wrong motor for your system. 
2. Contact your dealer. 
D4 Fan motor stalls 
   Valve #4 (Fig. 1) set too high 
   See MODULATING  
  
  
     
   ELEMENT SET UP 
D5 Auger motor 
   Valve #4 (Fig. 1) set too low 
   See MODULATING  
  
slows or stalls 
    
  ELEMENT SET UP 
  
too quickly 
     
     
D6 Fan & Auger work 
  
Electrical Problem 
     
  
but chute controls  1. Electrical connections to battery 
1. Ensure that the clamps are 
  
do not work 
    
  making proper connection. 
  
properly 
2. Breaker is tripped. 
2. Reset breaker. 
  
  
3. Connector from Sw to block not 
3. Ensure the connector is 
  
  
  contacting. 
  fully engaged.  Check for 
  
  
    
  broken wires. 
  
  
4. Connection to No-Load Valve #6 
4. Check all items in D6 
  
  
  (Fig. #1) is not making 
    
  
  
5. Diodes in switchbox are defective. 
5. Check for voltage through diodes 
  
  
6. Solenoid Valve Spool is stuck 
6. Replace #8a or 8b solenoid 
  
  
     
   cartridge. 
D7 Chute controls do  1. The No-Load pressurizing valve 
1. Back of the adjuster-screw 
  
not work properly 
  #14a (Fig. #1) set too low. 
  till it rotates freely by hand.  Then 
  
in no-load 
    
  turn in till you feel it contacting the 
  
conditions. 
    
  spring.  Then turn in 2 turns. 
  
  
2. Electrical:  Switch, harness,  
2. Check the No-Load Circuit 
  
  
  connectors, coil 10a, diodes 
  #5 in Fig. #2 
  
  
3. Polarity of the system is reversed. 
3. Red Alligator clip must be 
  
  
    
  on the Positive Terminal 
  
  
4. Diodes in switchbox defective. 
4. Replace defective diodes. 
  
  
5. Defective Coil #10a (Fig. #1) 
5. Replace Coil. 
  
  
6. Defective Valve #6 (Fig. #1) 
6. Replace Valve. 
D8 Chute Rotation  
1. See D7-1 
1. Same as D7-1. 
  
seems to lack  
2. Valve #14b or #14c set too low. 
2. Back of the adjuster-screw  
  
power to turn. 
    
  till it rotates freely by hand  
  
  
    
  then turn in till you feel it 
  
  
    
  contacting the spring.  Then 
  
  
     
   turn in 2 turns.