Bühler Commercial Snowblower ユーザーズマニュアル

ページ / 36
               
Commercial Snowblower 
 
 
8
HYDRAULIC CONTROL BLOCK 
 
NON-STALLING-FAN FEATURE: 
 
The Hydraulic Snowblower has a unique modulating element that keeps the blower fan 
from stalling in an overloaded condition.  This is accomplished by starving the hydraulic 
flow to the front auger motor (which then stops feeding the fan) and diverts all of the 
flow (and energy) to the main fan motor.  As the fan clears itself, and the pressure 
drops, the auger again begins feeding according to load.  When the system is set up 
properly the fan motor should not stall or plug up. 
 
MODULATING ELEMENT SETUP: 
For optimum performance the modulating element (#4) (Fig. 1) must be adjusted to 
match the system pressure of the tractor being used.  The factory setting is for a 2800-
3000 psi system.  If your system is less, you should make adjustments accordingly.  For 
adjustment: 
Loosen the LOCK NUT (on the MODULATING VALVE (#4) and back off the 
adjusting screw till the screw turns freely by hand, and then turn it in till you feel 
the screw making contact with the pressure spring.  One turn sets the pressure 
up by about 600 psi.   
 
For 2100 psi turn the screw in 3 ½ turns. 
 
For 2400 psi, turn in 4 turns 
 
For 2700 psi, turn in 4 ½ turns 
 
For 3000 psi, turn in 5 turns. 
 
If the fan stalls (in an over load condition), the (#6) element is set too high.  If the Auger 
slows and stops too soon, it is set too low.  Once it is set it should not need to be 
adjusted any more. 
 
Since there are a number of unknown variables that are unique to almost every 
situation, it is difficult to give an exact setting for a particular model.  The variables are:  
hose size and length, type and size of quick couplers, etc.