Whirlpool 240-VOLT ELECTRIC DRYER ユーザーズマニュアル

ページ / 20
4
INSTALLATION INSTRUCTIONS
Tools and Parts
Tools needed
Gather the required tools and parts before starting installation. 
Read and follow the safety instructions provided with any tools 
listed here.     
Parts supplied 
Remove parts package from the dryer drum. Check that all parts 
listed are included.
Parts needed
Check local codes, existing electrical supply and venting, and 
see “Venting Requirements” and “Electrical Requirements” 
before purchasing parts.
Location Requirements
You will need
A location that allows for proper exhaust installation. See 
“Venting Requirements.”
A separate 30-amp circuit.
A grounded electrical outlet located within 2 ft (61 cm) of 
either side of the dryer. See “Electrical Requirements.”
A sturdy floor to support the dryer weight (dryer and load) of 
115 lbs (52 kg). The combined weight of a companion 
appliance should also be considered.
A level floor with a maximum slope of 1" (2.5 cm) under entire 
dryer.
Do not operate your dryer at temperatures below 45ºF (7ºC). At 
lower temperatures, the dryer might not shut off at the end of an 
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will 
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, 
installation of the dryer in garages, closets, mobile homes, or 
sleeping quarters. Contact your local building inspector.
Installation Clearances
The location must be large enough to allow the dryer door to 
open fully.
Dryer Dimensions
*Most installations require a minimum 5½" (14.0 cm) clearance 
behind the dryer for the exhaust vent with elbows. See “Venting 
Requirements.”
Minimum installation spacing for recessed area and closet 
installation
The following dimensions shown are for the minimum spacing 
allowed when the dryer is to be operated with, or without, the 
Stack Kit. To purchase a Stack Kit, see “Assistance or Service.” 
Additional spacing should be considered for ease of 
installation and servicing.
Additional clearances might be required for wall, door, and 
floor moldings.
Flat-blade screwdriver
Level
Adjustable wrench
T20 Torx screwdriver
Wire stripper (direct wire 
installations)
Wood block
7 mm nutdriver
Caulking gun and 
compound (for installing 
new exhaust vent)
Tin snips (new vent 
installations)
Vent clamps
Coupling 
WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
33 ¼" 
(84.45 cm)
23 
³⁄₈
"
(59.37 cm)
39" 
(99.1 cm)
23 
¹⁄₄
"
(60.3 cm)
*