Bradford-White Corp D4504S*F(BN ユーザーズマニュアル

ページ / 40
Page 16 
Burner Cleaning Procedure (cont’d) 
Step 5. 
Remove the (4) 1/4” hex drive screws holding the 
right side inner door in place. 
Step 6.
Disconnect the pilot tube 
using a 7/16” wrench and the main burner
feedline with a 3/4” wrench from the gas 
control.
Step 7. 
Disconnect the spark igniter/flame sensor wire from 
gas control. 
Step 8. 
Remove the burner assembly from the combustion 
chamber.
Step 9.
Thoroughly inspect the burner surface area and 
burner port area and remove any loose debris. 
Step 10. 
Unscrew the burner from the main burner orifice. 
Step 11. 
Remove the main burner orifice from the main 
feedline using a 1/2” wrench.  Inspect the orifice and clean or 
replace, if necessary.
Burner Maintenance 
(4) 1/4” hex drive 
screws
Right side 
inner door 
Pilot and main 
feedlines 
Spark igniter/flame 
sensor wire 
Gas control
Burner assembly
Burner surface area 
and burner ports 
1/2” wrench 
Main burner 
orifice
Main feedline
16