The adapter provides 802.3 Ethernet connectivity, TCP/IP host 
connectivity, and Telnet application connectivity. 
Configuring The Terminal 
In order for the adapter to function successfully, the terminal 
should be configured as follows: 
Data Format 
8 data bits 
1 stop bit 
No parity  
EIA Baud Rate 
38400  
EIA Communication Protocol 
None 
Xon/Xoff 
DTR/DSR 
Both 
 
This setting should match the Comm Protocol setting of the 
adapter (see page 9). If the adapter’s Comm Protocol is set to 
None, the terminal could lose data. 
 
Emulation 
This adapter works with all the standard terminal 
emulations. However, the host emulation should match the 
terminal emulation. 
 
For example, a user logs on to a UNIX system, and selects 
the host emulation to be AT386 (using the command 
TERM=AT386 <CR> followed by set TERM<CR>). At this point, 
the user must make sure that the terminal emulation is also 
set to AT386 (by entering the terminal setup and checking 
the emulation parameter). 
 
A terminal in PC-Term emulation with Scan Code mode on, can 
not navigate the adapter setup menu. Change the key mode to 
ASCII or change the terminal emulation to other than PC-