2. Remove neutral ground wire from external ground conductor 
screw. Connect neutral ground wire and the neutral wire (white or 
center wire) of power supply cord under center, silver-colored 
terminal block screw. Tighten screw.
A. Neutral ground wire 
B. External ground conductor screw - Dotted line shows position 
of NEUTRAL ground wire before being moved to center, silver-
colored terminal block screw.
C. Center, silver-colored terminal block screw
D. Neutral wire (white or center wire) 
E.
3
/
4
" (19 mm) UL listed strain relief
B
A
3. Connect ground wire (green or bare) of power supply cord to 
external ground conductor screw. Tighten screw.
A. External ground conductor screw
B. Neutral ground wire
C. Ground wire (green or bare) of power supply cord
D. ¾" (19 mm) UL listed strain relief
E. Center, silver-colored terminal block screw
F. Neutral wire (white or center wire)
D
F
A
C
B
E
4. Connect the other wires to outer terminal block screws. Tighten 
screws. 
5. Tighten strain relief screws.
6. Insert tab of terminal block cover into slot of dryer rear panel. 
Secure cover with hold-down screw.
7. You have completed your electrical connection. Now go to 
“Venting Requirements.”
4-wire connection: Direct Wire 
IMPORTANT: A 4-wire connection is required for mobile homes and 
where local codes do not permit the use of 3 wire connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can 
be moved if needed. 
Strip 5" (127 mm) of outer covering from end of cable, leaving bare 
ground wire at 5" (127 mm). Cut 1
1
/
2
" (38 mm) from 3 remaining 
wires. Strip insulation back 1" (25 mm). Shape ends of wires into a 
hook shape.
     1"
(25 mm)
       5"
(127 mm)
When connecting to the terminal block, place the hooked end of the 
wire under the screw of the terminal block (hook facing right), 
squeeze hooked end together and tighten screw, as shown. 
1. Remove center, silver-colored terminal block screw.
2. Remove neutral ground wire from external ground conductor 
screw. Connect neutral ground wire and place the hooked end 
(hook facing right) of the neutral wire (white or center wire) of direct 
wire cable under the center screw of the terminal block. Squeeze 
hooked ends together. Tighten screw.
A
B
E
D
C
 
A. Neutral ground wire 
B. External ground conductor screw - Dotted line shows 
position of NEUTRAL ground wire before being moved to 
center, silver-colored terminal block screw.
C. Center, silver-colored terminal block screw
D. Neutral wire (white or center wire) 