Wegener Communications 6420 ユーザーズマニュアル

ページ / 135
 
 
iPump 6420 User’s Manual 
 
 
www.wegener.com 
800070-01 Rev B 
Chapter 3, Page 61 
Push Button Definitions 
The push buttons react differently based on what mode the user is in and what screen type is 
currently being displayed. The following table describes this interaction.  Note that this is a 
general guideline.  Exceptions will be noted in the individual IRD specifications. 
LCD Mode 
Push 
Button 
LCD Screen 
Type 
Function 
MENU 
Go to next lower level and display the first screen on that level. 
INFO 
N/A 
ENTER 
PARAMETER 
Enter EDIT mode and set cursor on first digit if alpha-numeric or 
blink entire field if field type is list select. EDIT mode is only 
entered if the user has the authorization to edit the parameter. 
ESCAPE (All) 
Go to previous (higher) level and display the current screen OR 
display the first screen at the current level if at the highest level. 
The first screen at the top level is the HOME screen. Therefore, 
pressing ESCAPE numerous times (or pressing and holding) will 
eventually return the user to the HOME screen. 
UP (All) 
N/A 
DOWN (All) 
N/A 
LEFT (All, 
except 
SCROLL 
INFO
Display the previous screen at the current level OR wrap to the 
last screen if currently on the first screen. 
RIGHT (All, 
except 
SCROLL 
INFO
Display the next screen at the current level OR wrap to the first 
screen if currently on the last screen. 
LEFT SCROLL 
INFO 
Scrolls to the left in a scrolled information screen. 
VIEW 
RIGHT SCROLL 
INFO 
Scrolls to the right in a scrolled information screen. 
ENTER PARAMETER 
If the user input is valid, the IRD accepts the changes that were 
made and enters the VIEW mode.  If the input was invalid, the 
IRD flashes an “Invalid Entry” message on the LCD momentarily 
before returning to the same screen in the EDIT mode again. 
ESCAPE PARAMETER 
Abort any changes made to the parameter and enter the VIEW 
mode. 
UP PARAMETER 
List Select: Scrolls up to next value in the list or wraps if currently 
on the last item in the list.  
Alpha-numeric: Increases the value of the current field. If numeric 
and the current value is 9 (if decimal) or 0xF (if hex), the value 
will wrap to a 0. If alpha-numeric, the value will wrap to the first 
ASCII value when at 0x7F. 
DOWN PARAMETER 
List Select: Scrolls down to previous value in the list or wraps to 
the last item if currently on the first item in the list.  
Alpha-numeric: Decreases the value of the current field. If 
numeric and the current value is 0, the value will wrap to 9 (if 
decimal) or to 0xF (if hex). If alpha-numeric, the value will wrap 
to the last ASCII value when at the first. 
LEFT PARAMETER 
List Select: N/A 
Alpha-numeric: Moves to the previous digit. Wraps to the last 
digit if currently on the first. 
EDIT 
RIGHT PARAMETER 
List Select: N/A 
Alpha-numeric: Moves to the next digit. Wraps to the first digit if 
currently on the last.