Worth Data 802 RF ユーザーズマニュアル

ページ / 119
8-3
Terminal Error Messages 
 
 
Message 
Meaning – Action Required 
Looking for App Server 
Please Wait  
This is a normal message, generated when the 
Terminal Device first tries to establish contact with a 
Server.  
 
TERMINAL OUT OF 
RANGE, PRESS ANY KEY
TO RETRY 
 
The Terminal is not within range of any Access Point –
regardless of SSID or encryption settings. Move closer 
or hold up to retry. If persistent, do a Site Survey. 
 
Server Not Available 
Press Any Key 
 
Terminal is configured to search for Application Server, 
but it could not find it. 
 
Looking for DHCP Server 
Please Wait 
Terminal is configured to get its IP address from a 
DHCP Server. It is broadcasting search. 
No DHCP Server Found 
Terminal is configured to obtain IP Address from DHCP 
Server, but it could not find a DHCP Server 
 WAITING ON HOST 
PROMPT, Please Wait 
The Server has been found. The host program has not 
sent out a prompt yet. If this lasts more than 6 seconds, 
check the host application program for a logic bug. 
Transmission Delayed, 
Press Any Key 
This is an indication that the Radio was reset by the 
firmware – normally a rare condition. If you see it more 
than once per week, please call us with information on 
what you were doing at the time it occurred. 
Server Shut Down Due to 
Host Logic Error,  
Press Any Key 
 
 
 
 
Problem is in host program. Notify programmer! 
If the Server detects 5 Sequence Errors in a row, or 5 
messages to a Terminal not Signed In, or 5 Illegal 
Commands, the Server transmits the message to all 
terminals signed in and shuts down. Check your host 
program and correct the logic error before starting up 
again.   
Server Re-initialized  
Press Any Key
 
The Server was rebooted. Press any key to be 
transferred to the Mode menu.  
LOW BATTERIES 
Finish, Sign Off 
Change Batteries 
Finish the transaction you have started. The Press F1 
to Sign Out. Then turn off the Terminal and change the 
batteries.  
CHANGE BATTERIES 
UNIT SHUT DOWN 
The terminal will display this message for 20 seconds, 
sign out, and turn off. 
Change the batteries immediately. Don’t let someone 
else pick it up and operate with partially recovered 
batteries 
Cannot Communicate with 
PIC Processor  
 
The Terminal cannot communicate with the radio's PIC 
processor. Cycle power. If message persists, call for 
RMA. 
Radio not Responding  
The terminal's radio is not responding, Call for an RMA.