Worth Data RF Laser ユーザーズマニュアル

ページ / 60
33 
Code 39 Advanced Features and Functions 
 
Mod 43 
Check Character
 
Standard Code 39 can be printed with a "Mod 43 Check Character". This 
Mod 43 check character cannot be used with Full ASCII Code 39. The check 
character is derived by assigning a value to each character in the data to be bar 
coded from the table as follows: 
 
Char 
value 
Char 
value 
Char 
value 
Char 
value 
11 
22 
33 
12 
23 
34 
13 
24 
35 
14 
25 
36 
15 
26 
37 
16 
27 
space 
38 
17 
28 
39 
18 
29 
40 
19 
30 
41 
20 
31 
42 
10 
21 
32 
 
 
Table C-1.  Mod 43 Check character calculation for Code 39 
 
Here is an example to illustrate how the check character is calculated for bar 
code data of 
123XYZ
  
1.  Take the sum of the values assigned to each character:  
 
1 + 2 + 3 + 33 + 34 + 35 = 108 
 
1     2     3      X     Y       Z 
 
 
2.  Divide the sum by 43: (thus the name modulus 43) 
108/43 = 2 with a Remainder of 22 
3.  Find the character corresponding with the remainder. 
M (value 22) is the CHECK CHARACTER 
The data becomes 
123XYZM
, with 
M