14
Pathfinder Radar Scanners
Power cable
The radome radar systems are intended for use on ships’ DC power 
systems operating in the 10.7 to 32 V DC range (that is, 12 V and 24 V 
systems, not 32 V systems). A 1.5 m (5 ft) power cable is supplied 
(with the display unit) for connecting the ship’s DC power to the radar 
scanner via the display unit. Refer to the HSB Series Display Owner’s 
Handbook for details on connecting this cable. This section provides 
details for extending the length of the power cable.
If a longer power cable run is required, use the supplied power cable 
to connect to the display unit. Then use a suitable connector block to 
connect the free end to the extension cable. The supplied power cable 
has a cross-section of 2.0 mm
2
.
Note: For vessels with 24 V power systems, the power cable may be 
extended by up to 20 m using a wire gauge of 1.5 mm
2
 (AWG 16) or 
greater, irrespective of the inter-unit cable length.
For vessels with 12 V power systems, longer power cable runs may 
require larger wire gauges to minimize any voltage drop in the cable. 
The scanner type and the length and type of the inter-unit cable (see 
tables) also affect the wire gauge required for the extension power 
cable. In order to determine the correct supply cable size if the power 
cable must be extended, estimate the length of cable between the 
ship’s main power source and the connector block, and then select the 
wire size indicated by the distance and inter-unit cable in the 
appropriate table following.
For example, you might have a 24" scanner, with 20 m between the 
scanner and display unit, that you plan to connect by extending the 
supplied 15 m heavy inter-unit cable with a 5 m extension cable. In 
addition, your 12 V power supply might be 10 m from the display 
unit, requiring an extension of 8.5 m. To determine the wire gauge 
required for the power cable extension, refer to the table for the 24" 
scanner, go to the row labelled 15 m Heavy + 5 m ext, and read across 
until you come to a maximum cable length greater than 8.5 m. This is 
the 10 m entry, in the column for 4.0 mm
2
 wire gauge.
154_4.book  Page 14  Wednesday, October 25, 2000  3:02 PM