Raritan Engineering Command Center CC-SG ユーザーズマニュアル

ページ / 270
188 C
OMMAND
C
ENTER 
S
ECURE 
G
ATEWAY 
A
DMINISTRATOR 
G
UIDE
 
 
 
 
Create a Cluster 
In the event of a failover, the administrator should send an email to all CC-SG users, notifying 
them to use the IP address of the “new” Primary CC-SG node.  
Important: It is recommended to backup your configuration on both nodes 
before setting up a cluster configuration.  
Set Primary CC-SG Node 
1.  On the Setup menu, click Cluster Configuration. The Cluster Configuration screen appears. 
2.  Click  Discover CommandCenters to scan and display all CC-SG appliances on the same 
subset as your one you are currently using. Alternatively, you can add a CC-SG, perhaps 
from a different subnet, by specifying an IP address in CommandCenter address in the 
bottom of the window. Click Add CommandCenter.  
 
Figure 232 Cluster Configuration Screen 
3.  Type a name for this cluster in Cluster Name. If you do not provide a name now, a default 
name will be provided, such as cluster192.168.51.124, when the cluster is created. 
4.  Click Create Cluster.  
5.  Click Yes when prompted if you want to continue. The CC-SG you currently are using will 
become the Primary node and a default name will be provided unless you previously entered 
one. 
 
Figure 233 Cluster Configuration – Primary Node Set