3.  Click  Configure  next to the serial port line item you wish to configure. The Configure 
Serial Port screen appears. 
 
Figure 24 Configure Serial Ports 
4.  Type a port name in Port Name field. Typically, you should name the port after the target 
server the device connects to, for example, NYC_MsSrv1.  
5.  Click on the Application Name drop-down menu and select an application name. This 
application, for example, Raritan Console (RC), is used to manage the target system.  
6.  Click on the Baud Rate drop-down arrow and select a rate. 
7.  Click on the Parity/Data Bits drop-down arrow and select a parity value. 
8.  Click on the Flow Control drop-down arrow and select a flow control value. 
9.  Click on the Associate Power Strip drop-down arrow and associate with a power strip if 
necessary. 
10. Select the associated category and element from the Port Associations table by double-
clicking the element field.  
11. Click  OK to save the serial port configuration. A Port Configured Successfully message 
confirms that port has been created. 
12. Repeat steps 1 through 11 to configure other serial ports.