Centurion CP72SR5 ユーザーズマニュアル

ページ / 36
29
TIMER and COUNTER SETTING
Various timers and counters can be programmed. The procedure is described
below in conjunction with Table 3, page 30.
STEP 1 - Ensure controller is in Programme Mode (see page 21).
STEP 2 - Press and hold the TEST pushbutton while monitoring LED L1.
STEP 3 - L1 will flash once then go off, twice in short succession then go off, 3 
times then go off, etc.
STEP 4 - Release TEST pushbutton when the desired MAIN MENU item in Table 
3 is required.
STEP 5 - To select required time (or count) hold TEST pushbutton while 
monitoring STATUS LED. After a short time STATUS will flash 
continuously and regularly. Each flash represents a unit of measure 
(i.e. time, distance or count).
Release TEST pushbutton when the required subdivision is selected. 
L2 will come ON to indicate that the controller is back in PROGRAMME 
MODE and another TIMER or FUNCTION (refer to procedure on page 
27) can be programmed.
STEP 6 -  Remove SET link when all programming is   complete.
*The PREFLASHING MODES mentioned on page 28  are described below:
      MODE 1 - COURTESY LIGHT PREFLASHES AT 1 HZ, THEN ACTS AS
                       COURTESY LIGHT.
      MODE 2 - COURTESY LIGHT FLASHES AT 1 HZ FOR PREFLASH TIME
                       AND THEN FLASHES IN SYNCHRONISM WITH THE STATUS LED
                       WHILE THE MOTOR RUNS.
      MODE 3 - COURTESY LIGHT ON CONTINUOUSLY FOR PREFLASH TIME
                       AND MOTOR RUN TIME ONLY.