Centurion CP72SR5 ユーザーズマニュアル

ページ / 36
6
MECHANICAL MOUNTING DETAILS
Option 1 - Bolt down onto concrete plinth
- Ensure motor does not protrude into drive-way install baseplate
  with centre line 250mm off pillar centre.
- Position baseplate (43) with centre of single support stud (45) 105mm
  from edge of gate (46). (This dimension assumes centre line of rack (47)  
  is 20mm from edge of gate).
- Using the baseplate as a template mark and drill the 4 mounting holes   
  into the concrete for the four M10 x 95 expansion studs.
- Use two M12 plated nuts per expansion stud as spacers below the 
  foundation plate.
- Secure the baseplate to the expansion studs using one M10 washer and 
  nut per expansion stud.
105mm
20mm
45
45
43
43
47
47
46
46
L
C