WAN Ports
5-15
WAN ports
WAN port User Screens and Settings
BERT
The Bit Error Rate Tester (BERT) sends a data pattern and measures the bit error rate (BER) 
on the selected WAN port. The patterns that can be selected are offmark (all ones), space 
(all zeros), 1:1 (0101), 1:7 (0100 0000), 3:24 (this pattern requires 3 bytes to display), qrss 
(quasi-random signal source), prb11 (pseudorandom binary sequence), prb15, and prb20.
SYNC
The Synchronization (SYNC) field tells you if the integrated BERT has achieved 
synchronization either with itself via a remote loopback or with the remote test equipment. 
Since this is an information-only field, there are no user-selectable parameters.
BE
The Bit Error (BE) field shows the total number of bit errors logged. Since this is an 
information-only field, there are no user-selectable parameters.
ES
The Errored Seconds (ES) field shows the total number of seconds in which any errors were 
detected. Since this is an information-only field, there are no user-selectable parameters.
SES
The Severely Errored Seconds (SES) field shows the total number of seconds in which the bit 
error rate exceeded one bit per thousand (1 x 10-
3
). Since this is an information-only field, 
there are no user-selectable parameters.
CSES
The Consecutive Severely Errored Seconds (CSES) field is triggered by the occurrence of ten 
consecutive Severely Errored Seconds. Once triggered, the CSES field will increment (by 
one) for each elapsed second until the system logs ten consecutive non-Severely Errored 
Seconds. Since this is an information-only field, there are no user-selectable parameters.
OSS
information only–no user options
BER
information only–no user options
ELAP
information only–no user options