Zhone IMACS-200 ユーザーズマニュアル

ページ / 294
6-6 
FXS Ports
Model No.
Running Head
PATTRN
The Pattern field selects an outgoing test pattern for the current port. The test pattern is 
generated by the system and sent to the selected port. You can select a different pattern for 
each port. The none option disables the test pattern. The D-mW (Digital milliwatt) option 
sends a 1 kHz tone at 0.0 dBm. The setting of the Rx TLP setting affects the D-mW signal 
level.
SIG CONV
The Signaling Conversion parameter allows you to change the transmit ABCD signaling bits 
from CCITT (E1) to ANSI (T1) standards, and is accessd by selecting B from the taBs option 
at the bottom of the window.
The options are off if ANSI signaling is used and on to convert transmit signaling from ANSI 
to CCITT format according to the Interface Card Conversion Table for FXS signaling. This 
setting also converts receive signaling from CCITT to ANSI. To see the options currently 
deployed on a port, Figure 6-3 shows the default settings for the conversion table. This table 
will be commonly used by all ports to which the this option is set to on.
The C->A column describes conversion done in the downstream direction towards the 
subscriber loop, while the A->C column describes the conversion done in the upstream 
direction, normally towards the T1 interface.
Figure 6-3.TABs Signal Conversion